background image

Step #1- Side tube installation-

Begin by placing the unit base (A) on the floor 

and insert the round side tubes (B) into the base grooves located on the top por-
tion of the base. See ILL. #1. Be sure that cavities on tubes are facing the inside 
of the unit. See ILL. #2. 

Step #2

- Carefully lay unit down and complete installation of the side tubes us-

ing two screws (H) and fully tightening with the enclosed Allan key wrench. 

Step #3- Caster installation –

Firmly insert stems of locking casters (G) into 

grooves at the two back ends of the base. See ILL. #3. Then firmly insert two 
non-locking casters (F) into grooves at the two front ends of the base. 

Step #4- Modesty panel installation-

Carefully stand up unit and choose de-

sired modesty panel (C) and carefully slide into the cavity on the two side tubes. 
See ILL. # 4.  

Step #5– Installation of lectern reading surface– 

Follow the below to com-

plete: 

A) 

Assembling reading surface to metal compartment

- Remove reading sur-

face from the carton and place on its underside.  Take metal compartment 
and align side holes to holes on reading surface using six Phillip head 
screws. Install compartment to reading surface. See ILL#5 

B) 

Front lectern panel installation

- Place metal compartment on a flat surface. 

Choose desired panel (D) and place in front of metal compartment. Install us-
ing a Philip screw driver and the four enclosed Philip head screws (I). Secure 
screws from back. See ILL #6. 

 

C)

 Lectern To Side Tube Installation- 

Place lectern top on top of side posts of 

unit assuring that holes on the underside of reading surface are aligned with 
holes on the top of side posts. Complete installation of the lectern reading sur-
face by using two screws (H) and fully tightening with the enclosed Allan key 
wrench. 

 

Отзывы: