INSTALLATION 

 
1.  Determine the location of the 

External IR (top or bottom of 
camera body). 

 

 

2.  Put the tiny bracket on the screw 

base. 
 

 

 

 

 

3.  Center the bracket position 

according to the two holes. 

 

 

4.  Screw it tightly. 

 

 

 

 

 

5.  Take the External IR and attach it to 

the bracket with the small screw tie. 
 

 

 

6.  Adjust the External IR to desired 

position (forward or backward and 
up or down). 

 

 
 
 
 
 
 
 
 
 

 

MADE IN TAIWAN

 

 

 

Copyright © 2013. All Rights Reserved. 

 

T-417_T-416-IR

 

www.okinausa.com 

R201311-V01

 

Содержание SDNR-8700

Страница 1: ...ns not included FEATURES 700 TV Lines 1 3 Sony Exview CCD II Digital Noise Reduction DNR Dramatically reduces both random and fixed noise It also reduces DVR disk space usage by up to 70 0 00039 Sens...

Страница 2: ...recycling of materials will help to conserve natural resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service...

Страница 3: ...the following conditions a When the power supply cord or plug is damaged b If liquid has been spilled or objects have fallen into the video product c If the video product has been exposed to rain or w...

Страница 4: ...D One 1 Motion Relay Output Wire E One 1 IRIS Connector F One 1 User Manual For any returns please include all components listed above with original packaging in Resalable Condition Absolutely No Retu...

Страница 5: ...ect Relay Output a Black Brown for External Alarm Device Set up on OSD Menu Special Motion Motion View On Off See page 11 for OSD setting and page 8 for application diagram b Red Orange not working fo...

Страница 6: ...ton Menu Setup Menu Description Menu Item Description Lens Defines the lens brightness and iris speed Exposure Defines the method of iris control Backlight Defines the highlight compensation HLC and b...

Страница 7: ...ns used with the camera Select DC to adjust the lens setting manually 1 Brightness Select the Brightness level value from 1 to 100 2 Iris Speed Select the iris speed value from 1 and 5 EXPOSURE In the...

Страница 8: ...ee details of objects in shadows or details of objects in bright areas of frames that have high contrast between light and dark areas such as the headlights of a passing car 1 Low level Set the low le...

Страница 9: ...ation the dome camera will then continue to display all colors correctly even when the color temperature of the scene changes such as from daylight to fluorescent lighting for example In the Setup men...

Страница 10: ...old level on how light it should be before switching from Night to Day mode The values range from 0 160 D N BW mode Select BW to manually set the camera to black and white mode 1 Burst Enable disable...

Страница 11: ...values range from 1 to 200 4 Sensitivity Set the Smart NR sensitivity for activation The values range from 1 to 200 SET DE FOG This feature will help to improve visibility of camera during poor weath...

Страница 12: ...et the level of gamma The values range from 0 05 to 1 00 FUNCTION There are additional functions available in this section In the main menu select function and press enter the below figure shows the d...

Страница 13: ...onfigure The selected zone will keep blinking 2 Area display Choose whether to enable motion detection for the selected zone If enabled you can also customize the position and size of the zone 3 Value...

Страница 14: ...f the privacy mask 3 Color Set the color of the privacy mask There are 16 colors available 4 Transparency Set the level of transparency of the privacy mask The values range from 0 to 3 0 means the mas...

Страница 15: ...om in times The values range from x2 to x5 2 Position Set the zoom area When a motion is detected it automatically zoom in out 3 Sensitivity Set the sensitivity level for activation Values range from...

Страница 16: ...In the image adjustment menu select sharpness to change the value by pressing LEFT or RIGHT 2 Monitor Select the monitor type which is closest to the type you are using In the Monitor submenu there ar...

Страница 17: ...om 0 60 2 H center set center location in horizontal side The values range from 0 255 3 V center set center location in vertical side The values range from 0 255 Defect In case the camera s image sens...

Страница 18: ...mera closes the lens automatically and detects defective pixels that exceed the specified level SETUP PROTOCOL ADJUSTMENT In function menu go to COMM ADJ the below figure shows the different options a...

Страница 19: ...mbination to enter the camera s OSD menu with OKINA USA s RS485 PTZ controller PTZ KB250X is SET 95 PRESET and for PTZ KB050X is PRESET 95 ENTER The protocol must be set to Pelco D not P For other RS4...

Страница 20: ...elect the OSD language There are 16 languages available press RIGHT or LEFT to choose the language ENGLISH KOREAN JAPANESE CHINESE TRADITIONNAL CHINESE SIMPLIFIED RUSSIAN FRENCH ESPANOL ITALIAN PORTUG...

Страница 21: ...onitor Lens shading Defect Electronic Shutter Auto 1 60 1 100 000 sec Flk X2 X256 Video Output 1 0 Vp p 75 ohm composite BNC Camera Title ON OFF Sens Up ON OFF Selectable limit 256X Picture Effect Fre...

Страница 22: ...ls detect low light the External IR is triggered and activates the camera s ICR to work simultaneously for best day and night images External IR can be mounted above or below the camera and can be aim...

Страница 23: ...External 5V trigger Depends on camera brand s own mode SWITCHES DIP Switch Settings 1 Reflection LED Power low high 2 Reflection LED off on 3 5 LED Power low high 4 5 LED Power off on VR Switch Setti...

Страница 24: ...e 3 Center the bracket position according to the two holes 4 Screw it tightly 5 Take the External IR and attach it to the bracket with the small screw tie 6 Adjust the External IR to desired position...

Отзывы: