DIP SWITCH SETTING
Before you install the camera, you should set the DIP switches to configure the
camera ID, communication protocol.
Camera ID Setup
ID number of camera is set using binary number. The example is shown
below.
Pin
1
2
3
4
5
6
7
8
ID Value
1 2 4 8 16
32
64
128
Ex) ID=5
Ex) ID=10
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
The range of ID is 1~255.
Do not use 0 as Camera ID
. Factory default is 1.
If you want to control a certain camera, you must match the camera ID with
the Cam ID setting of DVR or Controller
Communication Protocol Setup
Select the appropriate Protocol with DIP switch combination.