Quick Guide CU155+
22.08.2018
90532 2.0
3 / 3
GB
1.
Required testing equipment
Handset RF-Topline ID89746
–
(1)
Okimat IPS ID1.05.000.884.30
–
(2)
DUT (e.g. CU155+ ID89888)
–
(3)
Mains plug (EUR) ID3.00.401.125.30
–
(4)
Power down box (e.g. ID74389) (option)
–
(5)
LED-set (option)
–
(6)
2.
Preparation / Connecting
All pictures shown are for illustration purpose only
Actual product may vary
optional (MFP)
Po
w
er
d
ow
n
bo
x (
5)
LED-set (6)
End of testing
Button
Function
Direction
1
M1 out
Moves M1 out. The motor will run as long the button is pressed. And
the backlight turns on.
2
M1 in
Moves M1 in. The motor will run as long the button is pressed. And
the backlight turns on.
3
M2 out
Moves M2 out. The motor will run as long the button is pressed. And
the backlight turns on.
4
M2 in
Moves M2 in. The motor will run as long the button is pressed. And
the backlight turns on.
5
ZG / REJUVEN8
Fixed memory position ZG or REJUVEN8. Briefly press and than
release the button (press and release) drive M1 back to 20mm stroke
and M2 foot to 44mm stroke.
To stop the automatic drive any key can be pressed to stop.
6
Flat
Briefly press and then release the button (press and release), the M1
and M2 completely move in.
7
Memory-Position
1
By briefly pressing and immediately releasing the Memo 1 button
(Press and Release), the system moves to the stored position and the
backlight turns on.
8
Memory-Position
2
By briefly pressing and immediately releasing the Memo 2 button
(Press and Release), the system moves to the stored position and the
backlight turns on.
9
Memory-save
Press the button "Memory save button" once. Then within 3 seconds
desired memory button to be switched.The desired traversing position
is stored if the signal confirmations beep twice and the integrated UBB
on the controller flashes twice to confirm the completion of the storage
process.
10
UBB on / off
Switches external under bed ilumination at MFP-Port on /off.
UBB off - press button then UBB switch on.
UBB on - press button then UBB switch off.
The UBB automatically turns off after about 30min.
11
Flashlight on / off
Turn on the flashlight. As long as the button is pressed, the flashlight
is switched on. And the backlight turns on.
1 & 2
Paring
=> System 1
Press the function key on the control unit, 2x briefly.
The function / pairing LED lights up and the system is now in teach-in
mode for approx. 60 seconds. Then simultaneously press button 1
and button 2 on the RF transmitter. The LED starts flashing and
confirms the successful pairing process by a permanent LED light.
A beep on the control unit will signal the completion of the pairing
process.
1 & 2
UBB on / off
Switches external under bed ilumination at MFP-Port on /off.
UBB off - press button then UBB switch on.
UBB on - press button then UBB switch off.
The UBB automatically turns off after about 30min.
3 & 4
Paring
=> System 2
Option
Then simultaneously press the button 3 and button 4 on the RF
transmitter. The LED starts flashing and confirms the successful
pairing process by a permanent LED light.
A beep on the control unit will signal the completion of the pairing
process.
3 & 4
Wireless socket
on / off
Option
external wireless socket on / off.
Status of wireless socket switched off -> Simultaneously pressing
button 3 and button 4 switches on the socket.
Status of wireless socket switched on -> Simultaneously pressing the
button 3 and button 4 switches off the socket
brouillage est susceptible d'en compromettre le fonctionnement.