194
Advanced operations
Adjust the heaters temperatures
Each heater initial value is set in the media preset menu. These values are automatically set for the heaters temperatures.
Therefore, normally the heater control menu is not required.
The heater control menu is used to:
- Complete the temperature fine adjustment during the print operation; or
- Confirm the current heater temperature
Procedure to set the heaters temperatures
(1) The heaters are in standby at the initial
temperature registered with the media used.
>>AFTERHEATER T
↕
*50
→
50ºC
◎
>>PRINTHEATER T
↕
*40
→
40ºC
◎
>>PREHEATER T
↕
*45
→
45ºC
◎
When a media type is selected after installing the media, initial temperature
values of each heater for the selected media type are displayed on the
menu.
(2) Heating starts after receiving the data from
the RIP software.
RIP data
When the heaters temperatures are set with the print and job data from the
RIP software, the temperatures on the heater control menu are overwritten
by the temperatures from the RIP.
To use the initial temperatures set on the operation panel rather than
the temperature set with the RIP, set HEATER PRIORITY in the media
preset menu to PANEL SETTING.
(3) When the heaters temperatures have almost
reached the set temperatures, the print
operation starts.
When the current temperatures of the afterheater, printheater, and
preheater reach a temperature of 1ºC lower than the set temperature, the
printer starts printing.
The heaters maximum set temperatures are as follows.
Afterheater: 55ºC
Printheater: 55ºC
Preheater: 55ºC
Even after the print is completed, the temperatures changed during this
procedure remain as the heaters setup temperatures, until the media is
installed again or the printer is turned off.
However, the heater temperature settings in the media preset menu are
not changed.
(4) Changing the heaters temperatures during the
print operation.
↕■■
45 50
45ºC
Aft 40 +50
45Pre
HEATER
During the print operation the heaters temperatures may be changed by
specifying set temperatures in the heater control menu.