169
Advanced operations
10
Tighten the two securing screws.
Note
Securely tighten the head securing screws using a
flathead screwdriver.
If the head securing screws become loose, the print
heads may incline to the right or left, which may affect
the print quality.
11
AFTER CHANGING PH
HEIGHT, CLOSE COVER
Close the maintenance area cover and the
front cover.
CARRIAGE IS MOVING
PLEASE WAIT
Carriage stops moving.
12
ENTER PH HEIGHT
2
NORMAL
,
13
ENTER PH HEIGHT
2
HIGH
14
PH HEIGHT:HIGH
OK?
15
>PH MAINTENANCE
2
ADJUST PH HEIGHT
Notes
Do not move the head up/down mechanism with the head securing screws tightened. The head up/down mechanism
may break.
After changing the print head height, bidirectional printing may be slightly misaligned. In this case, adjust bidirectional
print positions with
BIDIR POSITION
in the
ADJUST
menu.
As the gap between the side plate of the printer and the carriage is narrow, if it is hard to reach the head up/down
mechanism and the head securing screws, move the carriage to the right (or the left) manually.
Confirm that the right and left head securing screws are tightened. If the carriage moves with the head securing screws
loosened, they may strike the media or edge guards, causing poor image quality and damage to the printer.
Always operate the two head up/down mechanisms at the same time and make sure that they are set to the same
position.
During adjustment of the head height, a warning beep will be issued.