Oki HCT-1000 Скачать руководство пользователя страница 9

8

 

 

2. 

To attach; screw the nozzle to the nozzle adapter (Figure 6, 3); tighten 
clockwise with Nozzle Wrench. 

3. 

To remove; unscrew the nozzle from the adapter (Figure 6, 3); loosen 
counterclockwise with Nozzle Wrench. 
 
 

3. 

Nozzle Selection 

1. 

Select the appropriate sized nozzle for the application. This is only a 
sample of the available nozzles. Please refer to the HCT-1000 Nozzle 
Selection Guide or visit our website 

www.okinternational.com

 for the 

complete selection.  

 

7. 

Operation 

1. 

De-Soldering Components using convection heat

 

1. 

Select the proper nozzle, and secure it to the adapter. 

2. 

Set the desired profile. 

3. 

Move  the  nozzle  close  to  the  component  leads;  maintain  3-5  mm 
distance. Use the hot air to melt the solder 

4. 

When  solder  is  molten,  use  the  integrated  vacuum,  tweezers  or  other 
suitable tool to remove the component from the circuit board 

2. 

Soldering Components using convection heat

 

1. 

Choose the proper nozzle, secure it to the adapter. 

2. 

Apply  the  right  amount  of  solder  to  the  circuit  board;  position  the 
component on the circuit board. 

3. 

Set the desired profile.  

4. 

Move the nozzle closer to the component leads, blow hot air onto the 
leads and melt the solder. 
 

8. 

Troubleshooting 

1. 

Unit does not power ON 

 

Check the power cord 

 

Check to see that you have mains voltage 

2. 

OH

 displayed on the LED screen 

 

Unit has exceeded the internal safety cut-off 

 

Allow unit to cool 

 

Check placement of thermocouple (if used) 

 

Reset the unit by cycling the power 

3. 

TCFAULT 

displayed on LED screen

 

 

Check location of thermocouple 

 

Ensure the thermocouple is firmly inserted into the correct TC 
connector 

 

Replace thermocouple if problem persists 

4. 

Flashing zone and temperature parameters while in Run Mode

 

 

Indicates the unit cannot meet the programmed time and 
temperature as set 

 

9. 

Maintenance 

The Hand-piece (HCT-HV1) will be part of OK International’s Service Exchange Program 
or the heater assembly (HCT-HTRASSY) can be purchased separately as a replacement 
part. 
 

HN-J0005, 

5.0MM 

HN-B1010 

10MM x 10MM 

HN-1818 

18MM x 18MM  

HN-B4040, 

40MM x 40MM 

Содержание HCT-1000

Страница 1: ...HCT 1000 HCT 1000 User Guide HCT 1000 Betriebsanleitung HCT 1000 Manuel d utilisation HCT 1000 Manuale dell utente HCT 1000 Gu a del usuario...

Страница 2: ...Safety Precautions Do not operate this unit in excess of maximum ratings settings Always wear appropriate personal protective clothing or apparel This equipment is for indoor use only Warranty OK Int...

Страница 3: ...tive humidity at 40 C 104 F System Modes HCT MRS Operational Modes Setup Run Manual Active Setup Memory Locations 50 Display LCD 20 X 4 display segments Description HCT PS1000 HCT 1000 Power Supply HC...

Страница 4: ...c 1 2 5 c R E M O V E Enter Profile Select Power On Off Timer Temperature Adjust Down Timer Temperature Adjust Up and Profile start abort Thermocouple TC1 Thermocouple TC2 Hand piece Connector Power...

Страница 5: ...mentarily Note you must be out of set up mode in order to do this I e no flashing numbers on the display 2 System Mode Selection The HCT 1000 has two system modes of operation The first mode is HCT In...

Страница 6: ...the Cool Down Zone you can only modify the Time parameter 4 Proceed to step 3 1 8 7 Manual Mode Setup 1 Use the buttons to change the temperature to the desired value Note continually pressing either...

Страница 7: ...ess the red on the footswitch or red button on the hand piece once the temperature in Z1 has started to flash 3 Profile will start to run and SETUP will be displayed on LCD 4 To modify the current zon...

Страница 8: ...e monitoring refer to 1 5 7 2 When using the HCT 1000 with external thermocouples in MRS mode TC1 on the HCT 1000 becomes the master thermocouple and is used to provide external feedback for the entir...

Страница 9: ...secure it to the adapter 2 Apply the right amount of solder to the circuit board position the component on the circuit board 3 Set the desired profile 4 Move the nozzle closer to the component leads...

Страница 10: ...9 Please visit OK International s web page www okinternational com where you will find additional information on systems accessories technical notes and more...

Страница 11: ...nicht au erhalb der maximalen Nennwerte Einstellungen betrieben werden Immer geeignete Schutzkleidung tragen Dieses Ger t ist nur zur Verwendung in Geb uden bestimmt Garantie OK International gew hrt...

Страница 12: ...Reduzierung der relativen Luftfeuchtigkeit bis zu 50 bei 40 C Systemmodi HCT MRS Betriebsarten Setup Betrieb Manuell Aktives Setup Speicherpl tze 50 Anzeige LCD mit vier 20 Zeichen langen Zeilen Besch...

Страница 13: ...M O V E T C 1 Zonensollwert Bisheriger Heizmesswert Temperatur berwachung Ausgew hltes Profil Zonenzieltemperatur Strom ein aus Zeitschalter Temperaturreduzierung Eingabe Profilauswahl Zeitschalter T...

Страница 14: ...ie das Ger t durch kurzes Dr cken des Netzschalters aus Hinweis Das Ger t darf sich hierbei nicht im Setup Modus befinden d h auf der Anzeige d rfen keine blinkenden Zahlen vorhanden sein 2 Auswahl de...

Страница 15: ...6 Einrichten des Betriebsmodus 1 Verwenden Sie die Tasten um den gew nschten Wert f r die Temperatur einzustellen Hinweis Durch 5 Sekunden langes Gedr ckthalten der Taste oder wird eine beschleunigte...

Страница 16: ...Heizung f hren 4 W hlen Sie das gew nschte Profil aus 5 Wenn das gew nschte Profil angezeigt ist dr cken Sie die Eingabetaste um das Profil auszuw hlen 6 Zum Starten des Profils dr cken Sie einmal auf...

Страница 17: ...auf dem L tgriffel um die Vakuumpumpe zu aktivieren und dr cken Sie erneut um sie zu deaktivieren 5 MRS Systemmodus Entfernen 1 Die integrierte Vakuumaufnahme aktiviert automatisch das Vakuum und zieh...

Страница 18: ...bbildung 6 1 fest damit der Adapter fest an der Heizer Baugruppe angebracht ist Falls der Adapter nach dem Anbringen abgenommen werden muss ffnen Sie die Klemme und schieben Sie den Adapter von der He...

Страница 19: ...9 HN J0005 5 0MM HN B1010 10MM x 10MM HN B1818 18MM x 18MM HN B4040 40MM x 40MM...

Страница 20: ...n 8 Problembehebung 1 Ger t schaltet sich nicht EIN Pr fen Sie das Netzkabel Pr fen Sie ob Netzspannung vorhanden ist 2 Auf der LED wird OH angezeigt Das Ger t hat die interne Sicherheitsabschaltgrenz...

Страница 21: ...ou endommag es l utilisation d accessoires ou d un quipement auxiliaire non agr s Pr cautions de s curit Ne d passez pas les capacit s r glages sup rieurs de cette unit Portez toujours une tenue de pr...

Страница 22: ...tive 40 C Modes du syst me HCT MRS Modes de fonctionnement Configuration Fonctionnement Manuel Configuration active Emplacements m moire 50 cran LCD 20 X 4 Segments d affichage Description HCT PS1000...

Страница 23: ...ne de zone Valeur de chauffe r elle Contr le de la temp rature Contr le du thermocouple Profil s lectionn Option de pose retrait Disponible en mode MRS seulement Temp rature cible de la zone Param tre...

Страница 24: ...u e 60 secondes minimum 7 Mettez l unit hors tension en appuyant bri vement sur le bouton d alimentation Remarque vous devez au pr alable quitter le mode de configuration aucun nombre ne doit plus cli...

Страница 25: ...rs passe en mode acc l r 2 Une fois la valeur d finie appuyez sur pour passer au param tre suivant 3 R p tez les tapes 3 1 6 1 et 3 1 6 2 jusqu ce que le profil soit programm Remarque dans la zone de...

Страница 26: ...secondes de refroidissement au minimum 3 Mode Configuration active 1 S lectionnez le profil modifier en suivant les tapes 1 3 pr c dentes 2 Pour activer le mode Configuration active appuyez sur penda...

Страница 27: ...ut tre utilis pour le suivi des temp ratures voir 1 5 7 2 Lorsque vous utilisez le HCT 1000 avec des thermocouples externes en mode MRS le TC1 du HCT 1000 devient le thermocouple ma tre et sert de r g...

Страница 28: ...nvection 1 S lectionnez l embout appropri et fixez le l adaptateur 2 Appliquez la bonne quantit de soudure sur le circuit imprim positionnez le composant sur le circuit imprim 3 S lectionnez le profil...

Страница 29: ...9 Visitez le site Web d OK International www okinternational com sur lequel vous trouverez entre autres des informations suppl mentaires sur les syst mes les accessoires et les notes techniques...

Страница 30: ...i Precauzioni per la sicurezza Non azionare questa unit superando i limiti massimi e le impostazioni indicate Indossare sempre indumenti o apparecchiature di protezione personale Questo apparecchio de...

Страница 31: ...uzione lineare per un umidit relativa del 50 a 40 C Modalit di sistema HCT MRS Modalit operative Impostazione Esecuzione Manuale Impostazione attiva Posizioni di memoria 50 Display LCD 20 x 4 Descrizi...

Страница 32: ...R I M U O V I T C 1 Punto impostato zona Lettura effettiva riscaldatore Controllo temperatura Controllo termocoppia Profilo selezionato Opzione posizionamento rimozione solo in modalit MRS Temperatura...

Страница 33: ...to ad un minimo di 60 secondi 7 Spegnere l unit premendo brevemente il tasto di alimentazione Nota a tale scopo necessario uscire dalla modalit di impostazione ovvero non devono apparire cifre lampegg...

Страница 34: ...della modalit Esecuzione 1 Utilizzare i tasti e per modificare la temperatura e portarla sul valore desiderato Nota tenendo premuto il tasto o per 5 secondi il conteggio crescente o decrescente viene...

Страница 35: ...del riscaldatore e il punto di regolazione della temperatura Per i profili in modalit Manuale viene visualizzato Manuale e non sar visualizzato il tempo residuo 8 Per uscire dal profilo tenere premut...

Страница 36: ...lit sistema MRS Indicatore di vuoto volumetrico 1 Sul display verr visualizzato V CA quando stato attivato il vuoto in modalit di impostazione o esecuzione Figura 4 La dicitura V CA lampeggia quando s...

Страница 37: ...timento completo fare riferimento alla guida di selezione degli ugelli HCT 1000 oppure visitare il nostro sito web all indirizzo www okinternational com 7 Funzionamento 1 Desaldatura dei componenti tr...

Страница 38: ...a se il problema non si risolve 4 I parametri relativi alla zona e alla temperatura lampeggiano in modalit Esecuzione Significa che l unit non pu utilizzare i tempi e le temperature impostati 9 Manute...

Страница 39: ...robados Precauciones de seguridad No opere esta unidad superando su respectiva capacidad y par metros de servicio m ximos Utilice en todo momento la ropa y el equipo de protecci n personal apropiados...

Страница 40: ...tiva a 40 C 104 F Modos del sistema HCT MRS Modos de funcionamiento Configuraci n ejecuci n manual configuraci n activa Ubicaciones de memoria 50 Pantalla LCD segmentos de pantalla de 20 X 4 Descripci...

Страница 41: ...eferencia de zona Lectura actual del calentador Supervisor de temperatura Control de termocupla Perfil seleccionado Opci n colocar retirar S lo disponible en modo MRS Temperatura objetivo de zona Par...

Страница 42: ...e la unidad manual por segunda vez se reducir el tiempo de enfriamiento a un m nimo de 60 segundos 7 Apague la unidad presionando el bot n de encendido por un momento Nota la unidad no debe estar en e...

Страница 43: ...la zona 1 comenzar a parpadear 5 Para la configuraci n del modo de ejecuci n contin e con el paso 3 1 6 1 para la configuraci n del modo manual contin e con el paso 3 1 7 1 6 Configuraci n del modo d...

Страница 44: ...jar de funcionar prematuramente 4 Seleccione el perfil de su inter s 5 Cuando aparezca el perfil elegido presione para seleccionarlo 6 Para iniciar el perfil presione el bot n rojo del interruptor de...

Страница 45: ...MRS colocaci n 1 Presione el bot n azul del interruptor de pedal o el bot n azul de la unidad manual una vez para activar la bomba de vac o vuelva a pulsar los botones para desactivarla 5 Modo de sis...

Страница 46: ...que el adaptador quede firmemente colocado en el conjunto del calentador Una vez ajustado para retirar el adaptador abra la abrazadera y deslice el adaptador para retirarlo del conjunto del calentado...

Страница 47: ...ura 8 Soluci n de problemas 1 La unidad no se enciende Revise el cable de alimentaci n Verifique que haya suministro de energ a 2 La pantalla LED muestra OH La unidad ha superado el valor de corte de...