BV1270SIP-OD OD Quick Start Guide

 

Oki Electric Industry Co.,Ltd. 

Page 3 of 33 

 
IMPORTANT SAFETY INSTRUCTIONS 

Warning 

 
 
This warning symbol means danger. You are in a situation that could cause bodily injury. Before 
you work  on any equipment, be aware of the hazards involved with electrical circuitry and be 
familiar with standard practices for preventing accidents. 

 
INSTRUCTIONS 

1. Read the installation instructions before connecting the system to the power source. 
 
2. Only trained and qualified personnel should be allowed to install, replace, or service this 
equipment. This equipment must be installed  
and maintained by service personnel as defined by EN60950. Incorrectly connecting this equipment 
to a general-purpose outlet could be hazardous. The telecommunications lines must be disconnected: 
1) before unplugging the main power connector or ; 
2) while the housing is open, or both. 
 
3. For connections outside the building where the equipment is installed, the following ports must 
be connected through an approved network termination unit with integral circuit protection. Before 
performing any of the following procedures, ensure that power is removed from the DC circuit. Do 
not work on the system or connect or disconnect cables during periods of lightning activity. 
 
4. To avoid electric shock, do not connect safety extra- low voltage (SELV) circuits to telephone-
network  voltage (TNV) circuits. LAN port contains SELV circuits, and telephone ports contain 
TNV circuits. 
Hazardous network voltages are present in telephone ports regardless of whether power to the unit 
is OFF  or ON. To avoid electric shock, use caution when working near telephone ports. When 
detaching cables, detach the end away from the unit first. 
 
5. To install the permanently fixed protective earthing during installation, earthing connection in 
this product should be directly connected to main supply socket with protective earthing in building 
or other specified device.

 

Содержание BV1270SIP-OD

Страница 1: ...lurlons For a Global Society Oki Electric Industry Co Ltd Quick Start Guide BV1270SIP OD E M5 Interface Internal Number to IP Address Translation SIP COMPATIBLE Firmware Ver 1 5 Maintenance Console So...

Страница 2: ...ce Gateway IP address numbering plan and all other parameters are for sample purposes only The guide configures the most basic required parameters For more advanced configurations please refer to the...

Страница 3: ...pen or both 3 For connections outside the building where the equipment is installed the following ports must be connected through an approved network termination unit with integral circuit protection...

Страница 4: ...to KTS PBX cables Step 2 Configuration 1 Unit Information Check firmware version If firmware version is old version you should do version up 2 Create Configuration File CONFIG DAT Set important basic...

Страница 5: ...must be prepared during the installation process In addition cable restraints should be installed Figure 1 1 BV1270SIP OD Ports Follow all instructions when performing cabling procedures Improper inst...

Страница 6: ...th the BV1270SIP OD base unit To install the power cable 1 Plug the DC connector on the AC adapter into the power connector located at the rear of the unit 2 Plug the power cable into the AC adapter F...

Страница 7: ...cross section 0 8mm2 If a crimp connector other than the one supplied with the BV1270SIP OD unit is to be obtained use one that is 1 25 4 for use with a 4mm diameter screw and terminal part width of 8...

Страница 8: ...Insert cores into RJ45 connector in accordance with the following diagram 8 7 6 5 4 3 2 1 1 SG Signal ground 2 SS Signal 3 Recieve PBX BV1270SIP OD E M5 4 Send BV1270SIP OD E M5 PBX 5 Send BV1270SIP...

Страница 9: ...BV1270SIP OD OD Quick Start Guide Oki Electric Industry Co Ltd Page 9 of 33...

Страница 10: ...d end of the cable to the PBX or similar remote equipment Figure 1 7 Connecting a unit to PBX E M5 trunk board To complete the installation all interface cables should be secured to the cable support...

Страница 11: ...ts 1 Locate the snap band wire tie packaged with the BV1270SIP OD base unit and the cable support bracket installed at the right side rear of the base unit On desktop units the bracket is attached to...

Страница 12: ...d directly to the unit using an RS 232C serial cable straight through with DB9 Female to DB9 Female connectors The pin configuration for the serial cable is shown in Figure 1 9 Figure 1 9 RS 232C pin...

Страница 13: ...1 If a port other than Com 1 is to be used the CMCS serial communications parameter must be reconfigured See Section 5 7 1 for details Figure 1 10 BV1270SIP OD serial port connection Notes The connec...

Страница 14: ...te LAN equipment e g router Ethernet switch or hub When connecting the BV1270SIP OD directly to a router use a 10BaseT Cross Rollover cable Use a 10 100BaseT straight cable to connect the BV1270SIP OD...

Страница 15: ...tialization process The Alarm and Busy lamps turn off following initialization and the Power and Online lamps remain lit If the Alarm and or Busy lamps remain lit for more than five minutes turn the u...

Страница 16: ...s sometimes necessary to turn the BV1270SIP OD unit OFF This is the case for instance during some forms of maintenance or when relocating the unit To turn the BV1270SIP OD power OFF pull up the power...

Страница 17: ...5 Cross Connect rollover cable 3 Connect the PC to BV1270SIP OD using the Serial RS232C cable Set the COM port settings to 9600bps 8 data bits 1 stop bit no parity Hardware control 4 Please note By de...

Страница 18: ...onnected to the BV1270SIP OD OD unit IVG Maintenance Console Software startup Flash screen Step 2 Enter mcs the default password Click OK Case sensitive password Step 3 Click on the Main folder in the...

Страница 19: ...rface OD Note Always select the FW version installed on your BV1270SIP OD Firmware version of B BV1270SIP OD should be the latest version Reference the BV1270SIP OD Installation Guide for more informa...

Страница 20: ...ll control signal UDP port number value of 5006 is the SIP VoIP standard Change it only if required Click Next Step 9 To select the default Maintenance Level Password mainte Click Next Case sensitive...

Страница 21: ...loaded to the BV1270SIP OD using the RS232C serial interface The BV1270SIP OD OD unit will reboot and the new settings will be in effect Step 11 Select Option 2 Select RS232C Click Finish Your PC shou...

Страница 22: ...mber 2 New york to San Jose Using a local extension off the PBX Access the PBX Station Ports connected to the New york BV1270SIP OD unit Dial 99 exstension number 3 San Jose BV1270SIP OD E M5 configur...

Страница 23: ...A backup file called CONFIG OLD is automatically created This is the Edit configuration Wizard A Tabbed Notebook Set to configure parameters related to the BV1270SIP OD E M unit The General Tab is the...

Страница 24: ...24 of 33 Step 15 Select Numbering tab Enter Office Code 99 Unique Unit ID 20 is the default Important 99 does not become part of the numbering plan Step 16 Select Trunk Data tab Configuring Ports 1 2...

Страница 25: ...nation Number 99 Enter Hunt Pattern no 1 Default is 1 note Click Update Important E M Hunt Group Code becomes part of the numbering plan note The Hunt Pattern relates to the Trunk groups setup on the...

Страница 26: ...ions only and are included here only as a reference Tone Tab Select from Tone libraries for US JP many EU countries and create Custom Tone Libraries Notify Email Tab Automatic email notification in ca...

Страница 27: ...oice Mode Tab Use this tab to set the Primary and Secondary CODEC s to use Also to adjust packet balances Fax related Tab T 38 TCP Fax related settings Numbering2 Tab Dialed Number conversion when Ori...

Страница 28: ...Control Tab Used to specify routing ports for VoIP calls Priority routing information Tab QOS Routing Support Set Type of service bytes TOS and Differential Services DiffServ DS byte Recovery Delay Ta...

Страница 29: ...the BV1270SIP OD units within the network registered in the DNS DAT file so that all the units can communicate with each other Please follow the attached flow chart if you are configuring multiple un...

Страница 30: ...rminal number 99 Remaining Digits 4 Note Comment San Jose E M Step 2 Select from Unit List New Network BV1270 OD Step 3 Click the button Step 4 Click OK Note The remaining digits value is the time the...

Страница 31: ...1 of 33 The above only saves the DNS DAT file on the PC Also if you are registering multiple BV1270SIP OD units please repeat Steps 21 22 for each unit By registering all units in your deployment ever...

Страница 32: ...of 33 STEP 3 File Transfer Step 24 Click BV1270 OD Right click mouse and select File Transfer Step 25 File Selection Wizard Select Config file CONFIG DAT Select DNS file DNS DAT Check Reboot after fi...

Страница 33: ...Guide Oki Electric Industry Co Ltd Page 33 of 33 Congratulations You have successfully completed the configuration of a BV1270SIP OD OD unit Step 26 Click Yes File transfer in progress Step 27 File t...