background image

Operation and Setting

Turn-on / Turn-off

Setting of Channel

1. Press “Power Switch”

 

key

 

(7)

 

for 1 second

 

to

 

turn

 

on

 

the

 

unit. The

 

LCD

 

window

 

will

 

    

show

 

“On”

 

first

 

and

 

then

 

show

 

channel

 

number

 

and

 

battery

 

life

 

indicator after 1

~

    seconds. The LED Power Indicator will be light

 

on

 

in

 

blue

 

as

 

well

.

2. Under any situation, the unit can be turned off if pressing “Power Switch”

 

key

 

(7)

 

    

for

 

more

 

than

 

2

 

seconds.

After turning on the unit, the current channel              

 

is

 

shown

 

on

 

the

 

LCD

 

window

Press  “Frequency  Set”

 

key

 

(3)

 

for

 

more

 

than

 

2

 

seconds

 

until  the  channel  number

 

              

starts to blink, and then press “Up”

 

or

 

“Down”

 

key

 

(5)

 

to

 

select

 

the

 

channel

 

from

 

1-96.

 

Press

 

“Frequency  Set”

 

key

 

(3)

 

again

 

to

 

confirm  the  setting  of  channel 

number or it will return back to the original channel number after 10 seconds without 
pressing any key.

HDC-702

The  performance  of  signal  transmission  is  highly  involved  with 
battery  energy.  Batteries  with  1600  mAh  (or  above)  in  capacity 
are  recommended. The optional charger  HDC-702 is an economy 
solution for you daily use.

CAUTION!!

Take out batteries when the devices won’t be operated in a long time.

DO NOT attempt to charge Alkaline battery. It will lead to battery 
leakage or even explosion!

Frequency Pairing

1. After turning on the unit, the frequency pairing will be run automatically once.  
2. The LED Power Indicator will be light on blinkingly in blue for three times and 

    

then constantly while frequency pairing successfully.  

3.  Press  “Frequency  Set”

 

key

 

for

 

less

 

than

 

2

 

seconds

 

to

 

enable

 

frequency

 

pairing

 

    

function

 

again

.  

If frequency pairing unsuccessfully after turning-on for 20 seconds, 

    

it will back to the original channel number with LED Power Indicator light

 

on

 

in

 

blue

 

    

constantly

 

and

 

the original channel number remained

 

without

 

blinking

.

4. The distance for

 

frequency

 

pairing

 

should

 

be

 

less

 

than

 

3

 

meters

.

10

Notice: This function is available while only working with DR-501A.

Wireless Handheld Mic EJ-701TS+/EJ-701TM+

Содержание UHF-PLL

Страница 1: ...UHF PLL Wireless Microphone System EJ 702DR PLUS Dual channel Receiver Single channel Diversity Receiver EJ 701DR PLUS User Manual ...

Страница 2: ...ates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction may cause harmful interference to radio communication However there is no grantee that interference will not occur in a particular installation If this equipment dose cause harmful interference to radio or television reception which can be determined by turning the equipment off and on...

Страница 3: ... Receiver Module 3 Antennas 4 Balanced AF XLR Output 5 Unbalanced AF Output 6 3 mm jack 6 AF Impedance Selection for 5 7 DC Power Socket 2 1 4 5 6 7 3 DC INPUT 12 15V 0 6A Single channel Diversity Receiver Illustration EJ 701DR PLUS 1 ...

Страница 4: ...al channel Receiver 1 Power Switch 2 DR 500 Wireless Receiver Module 3 Antennas 4 Balanced AF XLR Output 5 Unbalanced AF Output 6 3 mm jack 6 AF Impedance Selection for 5 7 DC Power Socket Power Supply Please use our product s AC Switching Adaptor as attached Illustration 2 ...

Страница 5: ...EJ 702DR PLUS Amplifier 2 If using XLR mic jack connect it from Balanced AF Output to amplifier s AUX IN In order to prevent from the impedance from being too high thus producing unexpected noise please set impedance at LOW if you are connecting a mic jack to a low input in the subordinate device 3 If your subordinate device is with general input socket e g LINE IN AUX IN etc please set impedance ...

Страница 6: ... adjustment made to it Change channel manually How SYNC works function can find a clean channel and assign it to transmitter in the range about 3 M Just turn on your microphone or transmitter first and press SYNC button in few seconds the progress will be done During synchronization the RF indicator will blink Please complete channel setup in one receiver first and then a second one when you have ...

Страница 7: ...n of Channels Press and hold SET key 4 to enterthe modeofselecting the channels 1 While both Channel A and Channel B are available the channel number of Channel A shown on LCD window starts to blink Press Up or Down Frequency Selector keys 3 to look for your preferred channel number Press SET key 4 again to confirm the channel setting 2 While only Channel A or Channel B is available switch the cha...

Страница 8: ...ency Selector keys 3 to look for your preferred group number 3 Press SET key 4 to confirm the group setting or wait for 5 seconds to confirm it automatically and then enter setting mode of SQ value 4 Under setting mode of SQ value LCD window will show number will keep blinking 5 Press Up or Down Frequency Selector keys 3 to choose SQ value the value will not be set in circulation 6 Press SET key 4...

Страница 9: ...3 the LCD window will show OFF with backlight on and then turn off After turning on the unit the current channel is shown on the LCD window Press Frequency Set key 8 for 2 seconds to until the channel number stats to blink and then press Up or Down key 10 to select the channel from 1 96 Press Frequency Set key 8 again to confirm the setting of channel or it will return back to the original channel...

Страница 10: ...essfully While changing to a new channel the LED Power Indicator will be light on in blue constantly 2 Press Frequency Set key 8 for less than 2 seconds to enable frequency pairing function again During the process of frequency pairing the LED Power Indicator will be light on in blue blinkingly together with channel number blinkingly shown on LCD window If frequency pairing successfully new channe...

Страница 11: ...tteries or 1 5 V Alkaline batteries Put the button cap 11 back CAUTION CAUTION Wireless Handheld Mic EJ 701TS EJ 701TM Put Batteries in Microphone 3 This action ensures the battery door is locked and to prevent from falling off Insert 2 pcs of 1 5 V AA alkaline batteries or 1 2 V AA rechargeable batteries into the battery case and then close the battery door 9 tightly DO NOT use larger capacity ba...

Страница 12: ...ved with battery energy Batteries with 1600 mAh or above in capacity are recommended The optional charger HDC 702 is an economy solution for you daily use CAUTION Take out batteries when the devices won t be operated in a long time DO NOT attempt to charge Alkaline battery It will lead to battery leakage or even explosion Frequency Pairing 1 After turning on the unit the frequency pairing will be ...

Страница 13: ...1TM to HI 2 Set level volume on corresponding receiver to max Adjust the output signal loop current on the loop amplifier according to standard 0dB at peaks Adjust the input signal on the loop amplifier until the IN indicator lits up The input signal is now sufficient to activate the AGC Do not adjust more than necessary as it might distort the signal 3 4 5 6 7 8 The chain transmitter receiver loo...

Страница 14: ...ransmitter and receiver are turned properly Be sure transmitter and receiver stay at same channel Remove battery from transmitter when you won t use it for a long while Charging contacts Clean charging contacts regularly to ensure good connection with charger When any corrosion occurs contact your dealer to change it if you can t repair it Important Notes Avoiding heat and humidity Replacing batte...

Страница 15: ...re than 8 M Use 4 channels at the same time Please keep the distance between the transmitter and the receiver more than 2 M Use 8 channels at the same time Please keep the distance between the transmitter and the receiver more than 8 M Use 12 channels at the same time Please keep the distance between the transmitter and the receiver more than 10 M 2 1 1 01 02 08 10 2 09 10 15 31 3 01 03 08 21 4 01...

Страница 16: ...equency 514 865 MHz country dependant Channels 16 96 frequency dependant LCD window Channel Frequency Channel adjustment select through UP and DOWN DR 500 EJ 701DR PLUS EJ 702DR PLUS Channel Reception Strength Frequency Set UP and DOWN Frequency modulation 24 MHz max T H D 0 5 70 100 M 60 90 M Dimensions DxWxH Weight Wireless Receiver Silent mode Tone key and noise lock dual squelch Power supply A...

Страница 17: ...batteries AF controls Power requirements Power supply 8 hours typical in Ni MH rechargeable batteries 14 hours typical in Alkaline disposable 10 mW Less than 250 nW Antenna RF output Built in antenna Spurious emission Hi Low Mute switch 237 g battery included 26 dia x 264 mm Dimensions ΦxL Weight 2 x 1 2 V Ni MH 1600 mAh AA type rechargeable batteries 2 x 1 5 V AA Alkaline disposable batteries AF ...

Страница 18: ...MEMO ...

Страница 19: ...MEMO ...

Страница 20: ...07 15 ...

Отзывы: