Adjusting salt consumption
6
1.
Activate the setup mode: Close the door within 60 seconds after power ON, press Start/Pause
button and hold for 5 seconds, the machine will enter setting mode which is indicated by the
alternatingly blinking indicator lights of
and .
2.
Adjust level of salt consumption: Press the Start/Reset button to select the proper setting
according to your local environment. Follow table below to find correct setting.
Water Hardness level
Setting
Digital display stalls
°dH
1)
mmol/l
2)
0-5
0-0.94
1
6-11
1.0-2.0
2
12-17
2.1-3.0
3
18-22
3.1-4.0
4 *
23-34
4.1-6.0
5
35-55
6.1 - 9.8
6
3.
The product will exit the setup mode automatically 5 seconds after last setting/operation of
switch.
Note:
1)
German degree of measurement for the water hardness
2)
Millimol, international unit for water hardness
*
)
Factory setting
Contact your local water board for information on the hardness of your water supply.