1
67101 05/11 (MBC)
Q U I C K G U I D E
Introduction
This thermostat can switch on your heating system at predetermined
times on different days of the week. For each day of the week, you can
set individual temperatures for 4 periods, called events. The thermostat
comes with a default schedule suitable for most installations. Unless you
change the settings, the thermostat will operate in compliance with the
default schedule. Lowering the temperature when the home is unoccu-
pied will reduce your energy costs without reducing comfort.
Furthermore, the thermostat features an adaptive function that auto-
matically changes heating period start times so as to ensure that the
required temperature is reached at the required time.
The full manual
can be downloaded at:
WWW.OJ-MICROLINE.COM/INTUITE
Up button
OK button
Down button
On/Off button
Reset GFCI
GFCI test button
FIRST TIME SETTINGS
• Time and day:
The first time you turn on the thermostat, time and day must be set.
The time flashes. Set the current time using the
Up
or
Down
button.
Then press the
OK
button to confirm the time. The day of the week
will then flash. Select the current day using the
Up
or
Down
button.
Press the
OK
button.
• Select Mode:
The thermostat features 3 different modes of temperature control:
Auto:
Controlled automatically via the 4-event schedule.
Override:
Change the temperature for a single event.
Manual:
Set a temperature manually. 4-event program is
cancelled.
Press OK to access Mode and select the required mode using the
Up
or
Down
button. Press the
OK
button.
• Select Schedule:
The weekly 4-event schedule:
5:2
: Mon-Fri with 4 events/Sat-Sun with 2 events.
6:1
: Mon-Sat with 4 events/Sun with 2 events.
7:0
: Mon-Sun with 4 individual events.
Press the
Up
or
Down
button until the
Schedule
option flashes.
Press
OK
and then press the
Up
or
Down
button until the required
program (
5:2
,
6:1
or
7:0
) flashes. Confirm with
OK
.
The thermostat is now ready for use.
How to program the thermostat
The thermostat is pre-programmed with a 4-event program, see Fac-
tory Settings below. The program can be adapted individually for the
following 4-events:
• when I wake up in the morning
• when I am away at work
• when I come home
• and at night
1 Press the
Up
or
Down
button until the
Program
option flashes.
Press the
OK
button.
2 Press the
Up
or
Down
button until the day(s) that you wish to
program flash in the lower part of the display, e.g.
Mon Tue
Wed Thu Fri
. Press
OK
.
3 The symbol for the first event
will now flash.
The hour will flash, allowing you to set the hour at which you
want the morning period to begin. Press the
Up
or
Down
button
until the required hour is displayed.
4 Press the
OK
button. The minutes will flash.
Press the
Up
or
Down
button until the required minutes are
displayed, press
OK
.
5 The temperature setting will now flash in the upper part of the
display. Press the
Up
or
Down
button to set the required tem-
perature. Press the
OK
button.
6 The symbol for the next event (e.g. at work) will now flash, allow-
ing you to set the time and temperature for this period of the day
by repeating steps 3-5.
7 Once the four events have been set for all days, the display will
return to the Program menu. Finally, select
Exit
to exit the
Pro-
gram
for a 5:2 schedule.
Ground Fault Circuit Interrupter (GFCI)
The thermostat has a built-in GFCI that ensures personal safety in case
of ground faults.
It is important that the GFCI is checked monthly. See full manual on
www.Oj-MICROLIne.COM/InTUITe.
Settings
The Settings option allows the following to be set:
Time:
Set the hour and minutes.
Day:
Set the actual day.
Child lock:
Activate the child lock. To unlock, press OK to
activate the menu, then hold the Up and Down
buttons simultaneously for 3 seconds.
°C / °F:
Choose between Celsius and Fahrenheit.
Application:
Select the type of control used:
Room/Floor/Regulator/Room limit*.
Offset temp:
Adjust the measured temperature.
Readout:
Readout of energy consumption in per cent,
software version and application.
Adaptive:
ensures the required temperature is reached at
the programmed time.
Display:
Select what is shown on the default display.
Factory reset:
Restore factory settings.
* Only UDG.
Exit Menu
The various menus and sub-menus contain an
Exit
option.
1 Press the
Up
or
Down
button until
Exit
flashes.
2 Press the
OK
button. You may have to repeat steps 1 and 2 to
return to the final
Exit
option.
Should you enter a menu by mistake, you can exit it again without
changing the setting by simply confirming the current setting, i.e. by
clicking the
OK
button.
Factory Settings for Automatic 5:2 Program
Days 1-5 (Monday - Friday)
Event
Time
Temperature
Morning
6:00 a.m. - 8:00 a.m.
77°F / 25°C
Out
8:00 a.m. - 4:00 p.m.
68°F / 20°C
Home
4:00 p.m. - 10:00 p.m.
77°F / 25°C
night
10:00 p.m. - 6:00 a.m.
68°F / 20°C
Days 6-7 (Saturday - Sunday)
Event
Time
Temperature
Day
8:00 a.m. - 11:00 p.m.
77°F / 25°C
night
11:00 p.m. - 08:00 a.m.
68°F / 20°C
English
The trademark is registered and belongs to OJ Electronics A/S · © 2011 OJ Electronics A/S
Type UCG/UDG