This option allows you to choose which sensor is used to
control the heating system If a factory reset is performed,
the thermostat will auto detect an external sensor
•
A:
With this setting, the internal room sensor inside
the thermostat, controls the heating system
•
F:
With this setting, the external floor sensor controls
the heating system
•
C:
With this setting, the thermostat operates as a
regulator and no sensors are used The setting is a
percentage of the full load in steps of 1%
Note that Floor Protection is not active when using
the thermostat as a regulator
•
AF:
With this setting, the internal room sensor controls
the heating system subject to maximum and
minimum limits for floor temperature
The maximum temperature limit protects wooden
floors from excessive heat
The minimum temperature limit prevents the floor
from becoming uncomfortably cold when heating
is not needed, such as in a bathroom Note that
this function will increase energy consumption
Floor limit temperatures are set in the “Li : Floor
Temperature Limit” menu
APP: Sensor Application 1/2
• Access the menu
• Scroll through the menu until you come to APP
• Press the middle button to enter the SENSOR
APPLICATION setting
• Use the top or bottom button to select the appli-
cation that fits your installation
• Confirm your choice with the middle button