5.
5.
Maintenance
Maintenance
5.1.
5.1.
Burner maintenance
Burner maintenance
Cut off electric current from the burner and close manual shut-off valves
always before any maintenance work. Cutting power is adequate when
just inspecting the device.
5.1.1
5.1.1
To maintain flawless operation it is recommended to do the following at least once a year:
To maintain flawless operation it is recommended to do the following at least once a year:
1.
Check the burner head extension and change if necessary.
2.
Check the diffuser disc and change if necessary.
3.
Clean the ignition electrodes and check their setting.
4.
Change the oil nozzle if it is worn or damaged.
5.
Check the position, condition and cleanness of the flame detector.
6.
Clean filters. Filters may have to be cleaned more often depending on circumstantial
conditions.
7.
Check the air dampers lock screws and the servomotor axle lock. Retighten if
necessary.
8.
Check and lubricate the joints on adjustment rods.
9.
Check the oil pump capacity.
10. Clean your burner from dust and moisture.
11. Check regularly the combustion characteristics by flue gas measurements (after
refilling of the storage tank or at least once a year).
12. Check if the oil tank needs to be cleaned. The oil tank must be cleaned at least every
4-5 years.
Correct installation and adjustments and regular maintenance ensure correct operation of
the burner.
.
Service the burner annually
.
Use only original spare parts. When ordering spare parts please give the burner type
and serial number indicated on the burner nameplate or manufacturing card
5.1.2
5.1.2
Note!
Note!
The burner contains electric and electronic components. Adhere to rules and regulations
from local authorities when disposing.
RPMARINES 30840641GB
41 (57)
5. Maintenance
Содержание RP-150 T
Страница 1: ...ARINE BURNERS 0 2 4 4 5 URNERS 20 4 20 4 20 4 41...