Air-conditioner
Air switch capacity
10A
16A
13A
25A
GWH18YE-S6DBA2A/O
GWH18ACE-S6DBA1A/O GWC24ACE-K6DNA1A/O
GWH24QE-K6DNA1E/O
GWH24QE-K6DNC2C/O GWH24QE-K6DNA1C/O
GWH24YE-K6DNA1A/O
GWH24YE-S6DBA2A/O
GWH24QE-K6DNA5X/O
GWH24AAE-K6DNA4Z/O GWH24YE-K6DNA1Z/O
Requirements for electric connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit.
2. According to the local safety regulations, use qualified power supply circuit and air switches.
3. Make sure the power supply matches with the requirement of air conditioner.
The power supply is unstable or the wiring is incorrect or faulty. Please install proper
power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety. For models with a power plug, make sure the plug is
within reach after installation.
6. Do not put through the power before finishing installation.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
8. The temperature of refrigerant circuit will be high, please keep the interconnec-
tion cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
10. Appliance shall be installed, operated and stored in a room with a floor area
larger than “X”m
2
(see table 1).
Grounding requirement
GWH12QB-K6DNB4Y/O
Please notice that the unit is filled with flammable gas R32. Inappropriate
treatment of the unit involves the risk of severe damages of people and
material. Details to this refrigerant are found in chapter “refrigerant”.
GWH09YD-S6DBA2A/O
GWH09ACC-S6DBA1A/O GWH09UB-K6DNA4A/O
GWC12ACC-K6DNA1D/O GWH12YD-S6DBA2A/O
GWH12UB-K6DNA4A/O
GWH12ACC-S6DBA1A/O GWH12QC-K6DNA1D/O
GWC18ACD-K6DNA1D/O
GWH18QD-K6DNA1C/O
GWH18QD-K6DNA1D/O
GWH18QD-K6DNC2C/O
GWH18YD-K6DNA1A/O
GWH18UC-K6DNA4A/O
GWH12QC-K6DNA5X/O
GWH12ACC-K6DNA1X/O GWH18YD-K6DNA1Z/O
GWH18QD-K6DNA5X/O
GWH09QB-K6DNA1C/O
GWH09QB-K6DNB8I/O
GWH09ACC-K6DNA1A/O
GWH09YC-K6DNA1A/O
GWH09QB-K6DNA1E/O
GWC09ACC-K6DNA1C/O
GWH09QB-K6DNB4Y/O
GWH12QC-K6DNA1C/O GWH12YC-K6DNA1A/O
GWH09YC-K6DNA1Z/O
GWH09QB-K6DNA5X/O
GWH09ACC-K6DNA1X/O
GWH12YC-K6DNA1Z/O
1. The air conditioner is the first class electric appliance. It must be properly
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
all poles should be connected in fixed wiring.
6. Including an air switch with suitable capacity, please note the following table. Air
switch should be included magnet buckle and heating buckle function, it can
prevent the circuit-short and overload. (Caution: please do not use the fuse only
for protect the circuit)
13
At least 3cm above the floor
Note:
●
Take sufficient protective measures when
installing the outdoor unit.
●
Make sure the support can withstand at least
four times of the unit weight.
●
The outdoor unit should be installed at least
3cm above the floor in order to install drain
joint.
(for the model with heating tube, the
installation height should be no less than 20cm.
)
●
For the unit with cooling capacity of 2,300W
~5,000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6,000W
~8,000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10,000W
~16,000W, 10 expansion screws are needed.
Installation of outdoor unit
Step one: fix the support of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
1. Place the outdoor unit on the
support.
2. Fix the foot holes of outdoor unit
with bolts.
Foot holes
Foot holes
Chassis
Outdoor drain joint
Drain vent
Drain hose
Step two: install drain joint
(Only for some models)
Step three: fix outdoor unit
1. Connect the outdoor drain joint into
the hole on the chassis, as shown in
the picture below.
2. Connect the drain hose into the drain vent.
NOTE: As for the shape of drainage joint,
please refer to the current product.
Do not install the drainage joint in the
severe cold area. Otherwise, it will be
frosted and then cause malfunction.