BRS-12A3 User Manual SCD/ATT Version 1.2 29-04-2019
19
6. Phase
Click this button to reverse the phase of the channel you are viewing. The button will be highlighted with a
box to show the function is active. Click the button again to change the phase back to 0°. The button will
change and the highlight will be removed.
7. Low pass
Click the tick box to add a low-pass
fi
lter to your preset. To enter a number, rapidly click 3 times on the
frequency box, press delete to clear the current data then enter your new frequency and press enter to
submit your change.
To alter the slope type, click the centre box to choose between a selection of different
fi
lter slopes.
To alter the slope rate, click the right box and choose between 2 and 10 to adjust the slope angle. Changes
are re
fl
ected in the graph.
8. High pass
Click the tick box to add a high-pass
fi
lter to your preset. To enter a number, rapidly click 3 times on the
frequency box, press delete to clear the current data then enter your new frequency and press enter to
submit your change.
To alter the slope type, click the centre box to choose between a selection of different
fi
lter slopes. To alter
the slope rate, click the right box and choose between 2 and 10 to adjust the slope angle. Changes are
re
fl
ected in the graph.
9. PEQ
This table is split into 10 columns. Clicking the number turns that
fi
lter on and off.
EQ type
- Click this box, then the drop-down triangle and a pop-up box will appear with a choice of
fi
lter
options are available.
Frequency
-
Click the box once, enter a number and press enter to change the frequency of that node.
Clicking the box and using the up/down keys on the keyboard or the right of the box allow incremental
changes. Minimum frequency is 20 Hz. Maximum is 24 kHz.
Gain
-
Adjust the gain of the
fi
lter by clicking on the gain box and entering a number followed by the Return
key. Minimum gain is -80dB, maximum is +20dB.
Quality
- Use this box to change the quality (width) of the
fi
lter slope. Click the box and enter a number
followed by enter to update the setting. 0.1 is maximum, 1000 is minimum width.
Reset
- This buttons resets the node to how it was before the settings were changed.
Any changes to the
fi
lter nodes mentioned above are re
fl
ected in the frequency view section. See below.
10. Frequency view
As nodes are altered and switched on or off, they will be populated in this section of the window to
demonstrate visually how you are altering the response of that channel. When a
fi
lter node has been
switched on, and is visible in the chart, you can click, hold and drag the node within the chart to make rough,
on-the-
fl
y adjustments to frequency response.
NB: Some
fi
lters and/or options are not available on all channels.