7. Periodical Maintenance
7.1 Check the below parts periodically.
HR
Check items
250
(1 month)
3000
(12
months)
6000
(24
months)
8000
(30
months)
Instructions
Intake Filter
Clean with brushes and
compressed air. (replace
once 6 months.)
V-belt loosen
Adjust and follow
instructions in operation
manual
Bolt(Nut) loosen
Tighten bolts(nuts) with
proper tools.
Must Do
Valve assembly
leaking
Inspect & clean spare
parts. Test if leaking or
not.
Compression ring
Check/Replace
Guide ring
Check/Replace
Connection Rod
a. Big end
b. Small end
If function well or any
noise
Cylinder
Check./Replace
Remarks:
1.
--- Check/Maintain, Replace when necessary
2.
--- Replace
7.2 Maintenance, repair or modifi cations must only be carried out by qualifi ed personnel
with authorized training.
1) When the air compressor is working under normal conditions, we recommend
to maintain as per above time table. If required, you may shorten the
maintenance interval.
2) To ensure effi cient compression, any piece of Compression Ring and Guide
Ring should be replaced if it’s worn-out as shown on the table below.
Spare
part
Ø130
Compression ring
Guide ring
The radial direction
thickness of new pieces
(mm)
10
2.4
The radial direction
thickness of worn-out
limit (mm)
8
1.8
Содержание P20-M
Страница 1: ...Air Compressor Operation Manual P20 M P25 M P30 M 255549 Rev 1 01 2014 ...
Страница 9: ...255549 Rev 1 02 2014 9 Appendix I Maintenance Record Date Hour Meter Record Service Tech ...
Страница 10: ...10 255549 Rev 1 01 2014 ...
Страница 12: ...12 255549 Rev 1 01 2014 ...
Страница 15: ...255549 Rev 1 02 2014 15 BLANK PAGE ...