4.3 Motor should follow regulations to be equipped with Magnetic switch and Overload
relay to avoid the motor current over pre-setting limit.
5. Operation
5.1 Checks before starting
1) Make sure that electrical connections comply with local electrical regulations.
2) Check set bolts and nuts to be securely tight.
3) Check V belt for proper tension.
4) Check that electrical cables are correct and securely tight.
5) Check that voltage is correct.
5.2 Checks under operation
1) If rotating direction of compressors is right.
2) If compressed air pressure rises normally while running.
3) If current of the motor remains within standard level under loading condition.
4) Stay away from extremely hot components.
6. Daily Maintenance
6.1 Clean the Belt Guard and the ventilation area of the air compressor frequently to
ensure proper cooling.
6.2 Inspect if there is unusual noise or if temperature is too high.
6.3 Check if there is abnormal vibration.
6.4 Check if voltage & current of the power supply are correct.