12
Trooper Count Scale
Using the numeric keys 0-9, enter the desired part
number. For this example, we will use 1230000000.
You will notice that the part number can be up to 12
digits and utilizes the DATA and COUNT display win-
dows. Press the
Enter
button to confirm the entry.
kg
g
lb
oz
Net
B/G %Ac
T
PT APW MR
M
<
>
PCS
WEIGHT
DATA
COUNT
BLINKING
BLINKING
3.4.2 Entering Data Directly into Library (Cont.)
Press the
M+
button, the display advances to APW.
Press the
Enter
button to access APW value.
Using the numeric keypad, enter the APW. Sample
shown indicates an average piece weight of 2g. Press
the
Enter
button to accept.
kg
g
lb
oz
Net
B/G %Ac
T
PT APW MR
M
<
>
PCS
WEIGHT
DATA
COUNT
BLINKING
kg
g
lb
oz
Net
B/G %Ac
T
PT APW MR
M
<
>
PCS
WEIGHT
DATA
COUNT
BLINKING
BLINKING
BLINKING
kg
g
lb
oz
Net
B/G %Ac
T
PT APW MR
M
<
>
PCS
WEIGHT
DATA
COUNT
BLINKING
BLINKING
kg
g
lb
oz
Net
B/G %Ac
T
PT APW MR
M
<
>
PCS
WEIGHT
DATA
COUNT
kg
g
lb
oz
Net
B/G %Ac
T
PT APW MR
M
<
>
PCS
WEIGHT
DATA
COUNT
Press the
M+
button to advance to setting the preset
tare. Press the
Enter
button to access the tare value.
Using the keypad, enter the desired tare weight. The
sample shown is 50g. Press the
Enter
button to ac-
cept.
Press the
M+
button to advance to Under count.
Press
Enter
button to access the under count value.
Using the numeric keypad, enter the desired under
count limit. For this sample, we will use 95. Press
the
Enter
button to accept.
kg
g
lb
oz
Net
B/G %Ac
T
PT APW MR
M
<
>
PCS
WEIGHT
DATA
COUNT
kg
g
lb
oz
Net
B/G %Ac
T
PT APW MR
M
<
>
PCS
WEIGHT
DATA
COUNT
BLINKING
BLINKING
kg
g
lb
oz
Net
B/G %Ac
T
PT APW MR
M
<
>
PCS
WEIGHT
DATA
COUNT
Press
M+
to advance to over count. In this sample,
we are using 105 pieces.
Press
Enter
button to access over count value. Using
the numerical keypad, enter the desired over count
limit (must be greater than under count value). Press
the
Enter
button to accept.
Содержание TROOPER COUNT
Страница 4: ......