STARTER 300 Portable pH Meter Instruction Manual
Страница 1: ...STARTER 300 Portable pH Meter Instruction Manual...
Страница 2: ......
Страница 3: ...libration 7 3 1 3 Performing 2 point calibration 8 3 2 Sample measurement 8 3 2 1 pH measurement 8 3 2 2 mV measurement 8 3 3 Temperature measurement 8 3 4 Using the memory 9 3 4 1 Storing a reading 9...
Страница 4: ...permanent installations Integrated labeling design for quick product identification IP54 protection against dust and water Ohaus renowned user friendly software 1 1 Safety measures Measures for your...
Страница 5: ...endpoint 3 Measurement icon measurement or calibration is running 4 Calibration icon calibration in progress 5 Setup icon instrument is in the setup mode 6 Battery status icon shows the condition of t...
Страница 6: ...Start calibration Review the latest calibration data Meter on Back to measurement screen Meter off Store current reading to memory Increase value during setting Scroll up through the memory Recall sto...
Страница 7: ...the batteries 1 Remove the battery cover screw and remove the battery cover 2 Insert the batteries in the battery compartment as shown 3 Replace the battery cover and tighten the battery cover screw...
Страница 8: ...p forward to lock in position Slide the shaft of the sensor into the clip from above 2 4 Installing the IP54 cover Use the small plastic tool as shown 2 5 Integrated stand for table top use One unique...
Страница 9: ...libration buffer and press Cal Cal 1 is blinking during calibration The calibration icon and the measurement icon appear on the display The measurement icon is blinking during calibration measurement...
Страница 10: ...is recommended If you use the MTC mode you should enter the correct temperature value and keep all buffer and sample solutions at the set temperature see 4 2 To ensure the most accurate pH measuremen...
Страница 11: ...confirm the deletion or press Exit to return to the measurement mode without deleting the data 4 Setup 4 1 Set endpoint mode The automatic endpoint is the default setting of the meter By pressing and...
Страница 12: ...t out of range Make sure the buffer is correct and fresh Clean or replace the pH electrode Error 5 Slope out of range Make sure the buffer is correct and fresh Clean or replace the pH electrode Error...
Страница 13: ...e to press the other keys until all the icons have disappeared When the self diagnosis has been completed successfully PAS appears If self diagnosis fails error message Err 1 appears Note You have to...
Страница 14: ...9 03 10 28 50 1 98 4 06 6 97 8 99 10 10 Buffer group b3 JJG119 Temp pH1 68 pH4 00 pH6 86 pH9 18 pH12 46 5 1 67 4 00 6 95 9 39 13 21 10 1 67 4 00 6 92 9 33 13 01 15 1 67 4 00 6 90 9 28 12 82 20 1 68 4...
Страница 15: ...Corporation 7 Campus Drive Suite 310 Parsippany NJ 07054 USA Tel 973 377 9000 Fax 973 944 7177 With offices worldwide www ohaus com PN 83033978 Ohaus Corporation 2011 all rights reserved 83033978 121...