Specifications

Model

CH15R11

CH30R11

CH60R11

CH60L11

CH100R11

CH150R11

CH300R11

Capacity x Readibility

(kg)*

15 x 0.002

30 x 0.005

60 x 0.01

60 x 0.01

100 x 0.02

150 x 0.02 300 x 0.05

  (lb)

30 x 0.005

60 x 0.01

120 x

0.02

120 x 0.02

200 x 0.05

300 x 0.05

600 x 0.1

Factory Set Resolution

1 : 7500

1 : 6000

1 : 6000

1 : 6000

1 : 5000

1 : 7500

1 : 6000

Max. Resolution

1 : 15000

1 : 15000

1 : 12000

1 : 12000

1 : 10000

1 : 15000

1 : 15000

NTEP Resolution

1 : 3000

1: 3000

1 : 3000

1 : 3000

1 : 2500

1 : 3000

1 : 3000

Load Cell - rated IP 65

50 kg

100 kg

250 kg

500 kg

Base size  (in/cm)

12 x 14 / 30.5 x 35.5

16 x 20 / 40 x 50

17 x 22 / 42 x 55

Platter Construction

Stainless steel 304

Base Structure

Black polyurethane painted steel

Column height       (in/cm)

Stainless Steel

14 / 35

28 /  70

Scale Weight         (lb/kg)

24 / 11

49  / 22

55  / 25

Shipping Weight

30  / 14

57 / 26

70 / 31

Display                                      (

(in/cm)

LCD    1/ 2.54 cm

Keyboard

4 function membrane switches

Power

9 VDC / 150 mA AC adapter or six alkaline C - type batteries

Typical battery life

250 hours / 100 hours continues use

Weighing units

g, kg, lb

Modes

Weighing & parts counting

Zeroing Range

2%, 18% or 100% capacity

Span Calibration

10%  to 100 %

Repeatability

+/- 0.0 1%  of the rated load

Linearity

+/ - 0.02 %  of the rated load

Safe Overload

150 %

Relative Humidity

10% - 95%

Operating Temperature

- 10

!

 C to 40

!

 C

Storage Temperature

- 20

!

 C to 60

!

 C

Item Ordering Number

CH15R11

CH30R11

CH60R11

CH60L11

CH100R11

CH150R11

CH300R11

* Factory set resolution.

 ** Model CH100R11 is factory calibrated for 100kg. Max. capacity is 150 kg .

    User selectable calibration is 150kg x 0.002

M

M

e

e

e

e

t

t

s

s

 

 

R

R

e

e

q

q

u

u

i

i

r

r

e

e

m

m

e

e

n

n

t

t

s

s

 

 

o

o

f

f

 

 

A

A

p

p

p

p

r

r

o

o

v

v

a

a

l

l

 

 

A

A

g

g

e

e

n

n

c

c

i

i

e

e

s

s

:

:

 

 

U

U

L

L

,

,

 

 

F

F

C

C

C

C

,

,

 

 

C

C

E

E

 

 

S

S

a

a

f

f

e

e

t

t

y

y

 

 

E

E

N

N

6

6

0

0

9

9

5

5

0

0

,

,

 

 

E

E

m

m

i

i

s

s

s

s

i

i

o

o

n

n

s

s

 

 

E

E

N

N

5

5

5

5

0

0

2

2

2

2

,

,

 

 

I

I

m

m

m

m

u

u

n

n

i

i

t

t

y

y

 

 

E

E

N

N

5

5

0

0

0

0

8

8

2

2

-

-

1

1

I

I

P

P

 

 

R

R

a

a

t

t

i

i

n

n

g

g

:

:

 

 

E

E

q

q

u

u

i

i

v

v

a

a

l

l

e

e

n

n

t

t

 

 

t

t

o

o

 

 

I

I

P

P

 

 

5

5

4

4

.

.

NTEP CERTIFIED : CD-11 INDICATOR NTEP NO. 99-100, CHAMP II BASE NTEP NO. 99-203

Содержание CHAMP II BASE

Страница 1: ...Ohaus Corporation 29 Hanover Road P O Box 900 Florham Park NJ 07932 0900 Phone 973 377 9000 Fax 973 593 0359 CHAMP II SCALE with CD11 Operating and Installation Instructions...

Страница 2: ...9 336 92 31 93 68 Compatibilit elettromagnetica EC1010 1 EN60950 1992 Safety Regulations IEC1010 1 EN60950 1992 Sicherheitsbestimmungen IEC1010 1 EN60950 1992 Consignes de s curit IEC1010 1 EN60950 19...

Страница 3: ...MFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE THIS DIGITAL APPARATUS DOES NOT EXCEED THE CLASS A LIMITS FOR RADIO NOISE EMISSIONS FROM DIGITA...

Страница 4: ...Capacity Ultimate Overload 300 of Full Capacity Operation Environment Champ II is designed to meet NTEP 3000d requirements to operate in a temperature range from 10 C to 40 C 0 to 95 relative humidity...

Страница 5: ...REMOVE THE RED PLASTIC SHIPPING TABS IN THE CORNERS OF THE SCALE BASE Troubleshooting If operational difficulties are encountered first obtain as much information as possible regarding the problem Fai...

Страница 6: ...ng a torque wrench tighten the hex bolts to the following torque specifications Model Torque CH15R 20 N m 15 Ft Ib CH30R 20 N m 15 Ft Ib CH60R 20 N m 15 Ft Ib CH60L 20 N m 15 Ft Ib CH100R 30 N m 22 Ft...

Страница 7: ...platform weigh within tolerance If the scale does not pass the shift test verify the overload stop gaps before replacing the load cell No adjustment for the shift is possible If the shift test cannot...

Страница 8: ...he field before use Parts list OHAUS PART NO DESCRIPTION 71129642 Indicator Bracket Assembly 71125105 Stainless Steel Column 350 mm high 71125103 Stainless Steel Column 680 mm high 71129064 Column Bra...

Страница 9: ...9...

Страница 10: ...e switches Power 9 VDC 150 mA AC adapter or six alkaline C type batteries Typical battery life 250 hours 100 hours continues use Weighing units g kg lb Modes Weighing parts counting Zeroing Range 2 18...

Страница 11: ...enetrating to the inside of the product or as a result of service or modification by other than Ohaus In lieu of a properly returned warranty registration card the warranty period shall begin on the d...

Отзывы: