Installation & Operation  

 

3.1

 

System ON and OFF 

 

Turn the fans on.  

 

Turn the key switch to on position. 

 

To turn the system off, turn the key switch to off position.  

 

3.2

 

Emergency Shut Off  

The emergency shut off button is located on the front of the panel.  

There is also a facility for remote shut off buttons to be wired in series on the circuit board. 

 

The emergency shut off button(s) will cut off the gas supply when activated.  

 

To reinstate the system, the emergency shut off button(s) will need to be reset and the panel 
restarted.  

 

3.3

 

BMS Integration 

The Merlin CT1200S can be integrated with a BMS to make or break a circuit on gas on/gas off, 
(valve open or valve closed). This will tell the BMS whether or not the kitchen has use of the gas 
supply.  

 

3.4

 

Fire Alarm Integration  

The Merlin CT1200S can be integrated with a fire alarm to close the gas supply automatically in 
the event of a signal from the fire alarm panel. 

 

The volt free fire alarm signal can be wired in series with any remote shut off buttons. 

If there are no remote buttons installed wire this directly to the terminal marked [EM REM]. 

 

 

3.5

 

Ventilation Mode  

There are two ventilation interlock operating modes. 

 

Mode 1

 - The panel is simply looking for a closed circuit from the air 

pressure differential switch, once the panel has a closed signal, the gas 
will come on. If the circuit is then opened the gas valve will close. 

 

Mode 2

 - The Panel needs to see a change in state of the pressure differential switch. Once the 

switch has gone from open to closed, the gas will come on. If the switch is already closed 
system will wait for the switch to open then close again before allowing the gas on. If the circuit 
is then opened the gas valve will close. 

 

OFF 

MODE 1 (Default) 

ON 

MODE 2 

 

 

 

Содержание Merlin CT1200S

Страница 1: ...ation Interlock system Installation Operation Maintenance Please read this manual carefully and retain for future use For specific requirements that may deviate from the information in this guide cont...

Страница 2: ...als 4 2 1 POWER IN 4 2 2 TO VALVE 4 2 3 TO BMS 4 2 4 EM REMOTE 4 2 5 FAN PD SWITCHES 4 3 Installation Operation 5 3 1 System ON and OFF 5 3 2 Emergency Shut Off 5 3 3 BMS Integration 5 3 4 Fire Alarm...

Страница 3: ...y holes into the case Important Warning Statements Never ignore your device when in alarm This device requires a continual supply of electrical power it will not work without power This device should...

Страница 4: ...on COM and normally open N O These are volt free connections 2 4 EM REMOTE The terminal for remote emergency shut off buttons is detailed on the circuit board as EM REMOTE These connections are linked...

Страница 5: ...4 Fire Alarm Integration The Merlin CT1200S can be integrated with a fire alarm to close the gas supply automatically in the event of a signal from the fire alarm panel The volt free fire alarm signa...

Страница 6: ...normal working the LED will illuminate GREEN If a supply fan fault is present the LED will be flashing If the LED flashes for more than 20 seconds the gas will be shut off ON OK FLASHING the supply f...

Страница 7: ...ice NEVER paint the device Paint will seal vents and interfere with the device 6 CT1200S Wiring Spec 1 POWER IN Mains Input 100 240VAC Single Phase 2 TO VALVE Gas Solenoid Valve Power Output 100 240VA...

Страница 8: ...warranty period In no event shall the manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consum...

Отзывы: