17
ERROR CODE PATTERN
There are two different error types:
• Generator errors (E1)
• Digital control errors(E2)
Generator errors are faults detected by the generator and forwarded to the control. On the display of the digital
control “E1” appears. On the analogue controls faults can be detected according to the duration and frequency
For example: error code E1 06 from the generator:
long
1
2
3
4
5
6
long
1
2
3
4
5
6
The red fault lamp remains on as long as an error exists.
Digital control errors are faults from the digital controls. On the display appears “E2” and than the error number.
FAULT MESSAGES FROM THE GENERATOR (E1)
Error.
N.
Name
Cause
Corrective action
E1
01
Hardware over
current
Unsuitable pan
material
Use suitable pan
material
Wrong or defective
coil
Check the coil
E1
02
No inductor current
Inductor connection
failure
Connect the
inductor properly
E1
03
IGBT temperature
too high
Air routes blocked
Fan clogged,
temperature
sensor of IGBT
defective
Clear air routes
Clean fan, check
fan rotation
E1
04
Cooking zone
temperature too
high or
too low
Pan empty
Remove pan, switch
off and wait a
couple of minutes
until the cooking
down
Temperature sensor
faulty
The sensor must be
replaced
Power board faulty
Replace the
generator
Содержание IIS4
Страница 1: ...FOR RESIDENTIAL AND PROFESSIONAL USE...
Страница 4: ...E Electrical connection Fig A 1 IIS4 INSTALLATION MANUAL 4...
Страница 5: ...Fig A 2 IIS8 E Electrical connection 5...
Страница 6: ...Fig A 3 IWS4 E Electrical connection 6...
Страница 7: ...CONNECTIONS OVERVIEW Fig B 7...
Страница 22: ...22...
Страница 23: ...23...
Страница 24: ...en...