Start-up / Shut-down
Before every Start-up:
Read and observe operation manual.
In order to guarantee proper function and trouble-free operation,
the following checks to be carried out before start-up:
•
General condition of the unit (connections, gaskets, etc.).
•
High pressure hoses, hose pipes, whether damaged.
•
Air supply, fresh air grill must not be covered.
•
Filling of consumables.
•
Correct oil level of high pressure pump (sight glass/dip stick). Correct oil
level of the reduction gear (sight glass/dip stick), correct oil level of
combustion engine (dip stick). Only oil qualities approved by OERTZEN
to be used. High pressure pump: special pump oil OERTZEN OSP,
reduction gear: special pump oil OERTZEN OSP, combustion engine:
OERTZEN special motor oil OSM.
•
Pump/pump connections whether leaking.
•
Machine only to be run with absolutely clean water. Before connecting
the water supply hose, rinse it thoroughly. Depending on feed water
quality, regularly check water filter in short intervals, replace if needed.
•
Machine only to be run horizontally (+/- 5°).
•
In order to extend the lifetime of the combustion engine, engine to be
warmed up for a few minutes during starting procedure and to run out
during shut-down for cooling purposes.
In order to guarantee proper function and trouble-free operation,
the following checks to be carried out during working:
•
Observe function of indicator lights/monitors.
•
Observe pressure variations
•
Observe leaks at high pressure pump, hose pipes, connections.
•
Observe excessive exhaust formation/smoke development.
In case of malfunctions immediately stop machine, eliminate cause
according to chapter „Trouble Shooting“, call qualified service.