9
Electric Connection
Connect the unit to a 230 V power source which is protected by 16 A (slow).
Extension cables to have a diameter according to VDE regulations. Extension
cables on reels to be reeled off completely, in order to avoid overheating of the
cable reel. Plugs, couplings to be water-proof. A faulty current protection
switch is recommended. VDE regulations apply.
High Pressure Connection
High pressure hose to be connected to high pressure outlet (11) of the
machine by means of the hand nut without using tools.
Fuel Tank Filling
Fill fuel tank (18) with clean fuel according to DIN 51603, part 1 or Diesel.
Ensure absolute cleanliness during transport and filling. Tank to be properly
closed after filling
Detergent Tank Filling (not included – to be provided by client)
Fill detergent tank with non-hazardous detergent. When using powders, these
have to be mixed in a separate tank before being filled into the detergent tank
of the machine. Tank to be properly closed after filling.
Operation
Open water source.
Unlock and release spray pistol, bleed the unit until blister-free water emerges.
Push ON/OFF switch (2).
Adjust burner/thermostat switch (23) to required working temperature.
Carry out cleaning task.
Be aware of recoil / ensure stable foothold. Observe hot exhaust fumes.
Model Compact 120 K is equipped with a circulation shut-down system.
Do not run the machine with closed pistol for more than 3 minutes, as
damage of the high pressure pump may be the result. During working
breaks the machine to be electrically switched off.