5.

 

Appliances in cascade  

In case of 

replacement

removal

 or 

addition

 of an electronic PCB on a device integrated in 

a cascade:  

  On 

OEtroCom-2

 (follower boiler) : no action required. 

 
 
 
 

  On 

OEtroCom-3 

(on master boiler): 

 

1.  Access the installer level: 

  Select   on the display 

  Enter code 

0012

 with the rotative button and confirm   

2.  Select the cascade icon 

 

 

3.  Select 

Yes

  

4.  Select 

Enable master func

 

5.  Select 

Confirm

  

6.  Select parameter 

System Bus autodetect

 

-  Autodetection is carried out 

-  The display indicates: 

System Bus autodetect performed

 

-  The main screen is displayed again when the automatic detection is completed 

-  All the PCBs present are recognized and visible in the different menus. 

 

  On 

OEtroCom-3 

(follower boiler) : see point 

3

 (page 2). 

Содержание OEtroCom-2

Страница 1: ...ng removing or adding an electronic PCB on one of the devices One of the following error codes appears H02 02 H02 03 H02 36 H02 37 H02 45 H02 46 2 On OEtroCom 2 control panel 1 If an error code is displayed clear the error by pressing the RESET key 2 Press the 2 right hand keys to access the Installer Menu 3 Enter the code 0012 4 If more than one electronic PCB is displayed select the main PCB EHC...

Страница 2: ...ton and confirm 2 Press key 3 Select Advanced Service Menu 4 Select Auto Detect 5 Select Confirm Autodetection is carried out The display indicates Performing autodetect The main screen is displayed again when the automatic detection is completed All the PCBs present on the device are recognized and visible in the different menus ...

Страница 3: ...lect installer icon and confirm with the button Enter code 0012 and validate with 2 Select Advanced menu 3 Select Auto detect with button 4 Select Confirm with button When the autodetection is finished the main screen is displayed again The system restarts automatically All the PCBs present on the device are recognized and visible in the different menus The list of the present PCBs is visible in t...

Страница 4: ... the display Enter code 0012 with the rotative button and confirm 2 Select the cascade icon 3 Select Yes 4 Select Enable master func 5 Select Confirm 6 Select parameter System Bus autodetect Autodetection is carried out The display indicates System Bus autodetect performed The main screen is displayed again when the automatic detection is completed All the PCBs present are recognized and visible i...

Отзывы: