1.1.10 System/Machine Specific Safety Instructions
WARNING
Leakage of liquid under pressure!
The pump's functionality may lead to pressures at the inlet and the outlet of
the pump which may damage the pump and/or the system and pose a risk
to persons.
▶
It must therefore be ensured that the max. permissible pressures at the
pump inlet and outlet are not exceeded. The allowed pressures are
specified in the pump data sheet (see
WARNING
Risk of fire due to dripping media
▶
Flammable media have to be prevented from dripping into areas, which
are subject to ignition. If necessary, place a protective pan under the
pump unit. The pan has to be permanently checked for leakage.
▶
The ignition temperature of the pumping, flushing and sealing media
must be at least 50°C higher than the operating temperature of the pump.
WARNING
Risk of electric shock
Incorrectly wired electrical connections may cause electric shock.
▪
Maintenance or repair of electrical components must only be performed
by qualified electricians.
WARNING
Risk of splintering due to breakage!
An excessive driving torque may cause drive shaft breakage.
▶
Please observe the max. allowed driving torque (see
).
▶
The pump is lubricated by the medium pumped. Do not allow the pump
to run dry!
▶
Do not remove any protective covers of rotating parts during operation.
Eccentric screw pump
Assembly Instructions, 09.22
09/2022 Released
TDD-00035234 1-051-8387
4
1 Mounting instructions