English 11 English
20. Wire Diameter or Manual Mode Selection Button: Sets
the diameter of the welding wire for Synergic Mode or
choose Manual Mode.
Process Symbol
Description
0.6
Available wire diameter depends
on choosing gas shielding type,
type of wire and welding wire
material.
0.8
0.9
1.0
1.2
The machine works in Manual
mode. Welding parameters (wire
feed speed and voltage) are
selected by the user.
21. Wire Material Selection Button: sets the type of wire
materials (for Synergic Mode only):
Process Symbol
Description
Fe Steel
Al Aluminum
SS Stainless
steel
22. Burnback Time Selection Button – for Synergic and
Manual Mode, allow to choose and set burnback time:
Process Symbol
Description
Burnback Time - amount of time
that the welding is continued after
the wire stops feeding. It prevents
the wire from sticking in the puddle
and prepares the end of the wire
for the next arc ignition.
Regulation range: from 0,02 to
0,25 seconds.
23. Welding Wire Type Selection Button: Set welding wire
type (for Synergic Mode only):
Process Symbol
Description
For Synergic Mode only
Gas shield required
24. Run-In WFS Button: Allow to show and set the Run-in
wire feed speed value (for Synergic and Manual Mode):
Process Symbol
Description
Run-in WFS – sets the wire feed
speed from the time the trigger is
pulled until an arc is established.
Adjust range: from 20 to 100
percent of the WFS value.
When Run-In value is more
than max WFS, machine keep
max WFS.
25. Gas Selection Button: Enables the selection of the type
of shielding gas (for Synergic Mode only).
Process Symbol
Description
To choose gas shielding.
26. Selection Button to Display Workpoint as WFS or A:
Allows to change the operating point display as wire
feed speed (WFS) in [m/min] or as an output current
value in [A]. Only available in synergic mode.
Process Symbol
Description
Workpoint values are displayed in
m/min.
Workpoint values are displayed as an
amperage [A].