background image

D - MAINTENANCE

D

- 20

CITOARC AP 217/ AP 225

3. SPARE PARTS

Kg.

Item

Sch.

CITOARC

AP 217

CITOARC

AP 225

Ref.

Ref.

Description

Front panel

1

CM1

x

x

SA 0016-2073 On/Off switch with lever

2

CM2

x

SA 0016-5002 2-range selector-switch

3

V1

x

x

SA 0012-1023 green led

4

V2

x

x

SA 0012-1029 Yellow led

5

V3

x

x

SA 0012-1030 red  led

6

BP1

x

x

SA 0016-1011 Reset push button

7

x

x

SA 0036-3001 Pressure gauge

Internal items

Control compartment

8

CC1

x

x

SA 0408-6286 Cycle card

9

CHF1

x

x

SA 0408-2527 Card HF

10

TA1

x

x

SA 0017-1088 Transformator power supply

auxiliary

11

F1

x

x

SA 0020-1024 Fuse-holder

12

L2

x

x

SA 0408-6401 Transformator H F

13

CT1

x

x

SA 0011-2018 Contractor primary

ST3

x

SA 0020-6017 75-60° thermal protector

14

EV1

x

x

SA 0036-0015 24V ~

‡

 2.5 solenoid valve

15

x

x

SA 0036-2004 Pressure switch

16

x

x

SA 0036-5006 Air regulator filter

F1

x

x

SA 0020-0050 Auxiliary 2A fuse

F2 - F3

x

x

SA 0020-0008 3A cycle card fuse

F4

x

x

SA 0020-0018 2A HF card fuse

Power compartment

17

MV1

x

x

SA 0010-1541 Fan motor

18

x

x

SA 0340-3371

‡

 300 propeller

19

PD1

x

x

SA 0018-2023 60 A – 1200 three-phase diode

bridge

ST1-2

x

x

SA 0151-3017 130-86° thermal protector

SH1

x

x

SA 0035-3012 160 A-100 mV shunt

20

TP1

x

x

SA 0408-6451 AP 217/225 power

transformer

21

R3

x

x

SA 0019-1065 10

:

-200W pilot arc resistor

22

R4

x

x

SA 0019-1063 Resistor, for help in striking,

8.2

:

 -10

C1-C2

x

x

SA 8811-0094 2.2nf 3KV decoupling

capacitors

23

R1-R2

x

SA 0019-1082 1.1

:

  - 3.5KW range resistor

x

x

SA 0018-6005 375V DC 0.6W peak limiter

x

SA 8573-2500 AP 217 wear parts set

x

SA 8573-2600 AP 225 wear parts set

Содержание citoarc AP 217

Страница 1: ...AP 217 AP 225 SAFETY INSTRUCTION FOR USE AND MAINTENANCE EDITION GB Instructions for use REF SA 8695 0848 REVISION C DATE 01 2002 ...

Страница 2: ...Arc welding and plasma cutting may be dangerous for the operator and persons close to the work area Read the operating manual ...

Страница 3: ...IRE 5 6 SAFETY IN THE USE OF GASES 6 7 SAFETY OF PERSONS 7 A GENERAL INFORMATION 8 1 CONSTITUENT ITEMS OF BASIC ASSEMBLY 8 2 DESCRIPTION 9 3 TECHNICAL SPECIFICATIONS 10 B STARTING UP 12 1 ELECTRICAL CONNECTION 12 2 COMPRESSED AIR CONNECTION 12 C INSTRUCTIONS FOR USE 14 1 STARTING UP 14 2 DESCRIPTION OF FUNCTIONS 15 3 POWER SOURCE WEAR PARTS SET 16 D MAINTENANCE 18 1 MAINTENANCE OF THE AP 217 AP 22...

Страница 4: ...2 CITOARC AP 217 AP 225 ...

Страница 5: ...defining the essential requirements for health and safety included in the French Labor Regulations Art L233 5 Decrees dated December 29th 1992 OERLIKON may not be held liable for any combination of items which it has not recommended For your safety we are providing below a non exhaustive list of recommendations or obligations a substantial part of which is included in the Labor Regulations OERLIKO...

Страница 6: ...arked Ö reinforcing of individual protection c Maintenance Troubleshooting Before any internal verifications and repair work make sure that the equipment is separated from the electric installation by electrical isolation by electrical isolation is meant a group of operations designed to separate and keep the equipment de energized Some equipment has a HV HF striking circuit indicated by a plate Y...

Страница 7: ...rally used in current welding practice 4 PROTECTION FROM NOISE Noise emitted by a welding or cutting machine depends on several parameters and particularly the welding cutting intensity the process MIG MIG PULSE TIG and so forth and the environment premises which or more or less spacious reverberation from the walls and so forth The no load noise from OERLIKON welding cutting power sources is gene...

Страница 8: ...ment which is designed for the gas used Ö check that the cylinder and the pressure reducing valve correspond to the gas necessary for the process Ö never lubricate the cocks handle them gently Ö pressure reducing valve do not forget to bleed the cylinder cocks before connecting the pressure reducing valve make sure that the pressure reducing screw is loosened before connection to the cylinder chec...

Страница 9: ...flame is almost invisible risks of burns Air hydrogen and oxygen hydrogen mixtures are explosive within extended percentage ranges Ö 4 to 74 5 hydrogen in the air Ö 4 to 94 hydrogen in oxygen Store the cylinders in the open air or in well ventilated premises Avoid leaks by limiting the number of fittings as much as possible Hydrogen makes certain metals brittle highly alloyed steels unkilled coppe...

Страница 10: ...17 ref SA 0408 2917 and CITOARC AP 225 ref SA 0408 2929 are equipped with 1 length 3 m 4x4 mm primary cable 1 length 3 m 16mm secondary cable with earth socket 1 compressed air hose 3m 1 torch length 6m ref SA0408 9530 1 kit of wear parts 1 safety instruction for use and maintenance ref SA 8695 0848 ...

Страница 11: ...e verification 3 Air pressure gauge 4 On Off lamp 5 Torch safety reset pushbutton and lamp torch 6 Power range selection 7 Regulator filter pressure adjustment 8 Air intake hose 9 Lifting eyebolts 10 Power supply cable IMPORTANT always use 2 slinging attachments to lift the power source 1 4 1 4 3 3 5 5 2 6 9 10 8 7 2 ...

Страница 12: ... t 25 C Gamme 1 40 45 100 100 Gamme 2 40 45 Gamme 3 Size L x W x h 615 x 530 x 885 615 x 530 x 885 Net weight 85 kg 85 kg Packaged weight 105 kg 105 kg Degree of protection IP 23 IP 23 Insulation class H H Standard EN 60974 1 EN 50192 EN 60974 1 EN 50192 Degrees of protection provided by the covering Code letter IP Equipment protection First number 2 Against the penetration of solid foreign bodies...

Страница 13: ...A GENERAL INFORMATION CITOARC AP 217 AP 225 A 11 Technical specifications of torch CP 40R Ö refer to instructions for use of torch ref SA 8695 0260 h l L ...

Страница 14: ... a 3 phase earth socket Check the size of the fuses according to the currents indicated on page 10 Connect your site or workpiece for cutting to your earth circuit as laid down in chapter SAFETY INSTRUCTIONS 2 COMPRESSED AIR CONNECTION Connect the air inlet pipe to your compressed air network using the quick fit connector Ö Minimum pressure 5 bars Ö Maximum pressure 6 bars Ö Service pressure 5 5 b...

Страница 15: ...B STARTING UP CITOARC AP 217 AP 225 B 13 ...

Страница 16: ...CITOARC AP 225 The nozzle diameter should correspond with the range of intensity current chosen Tips Given below are tables to help you in the choice of ranges and nozzles to be used depending on the thickness of the cut CITOARC AP 217 CITOARC AP 225 The CITOARC AP 217 has a maximum cutting capacity of 17 mm The CITOARC AP 225 has a maximum cutting capacity of 25mm It has 2 cutting ranges Use a sh...

Страница 17: ...t metal metal spatter can come into contact with the nozzle and damage it To avoid this direct the torch so that the metal particles are ejected sideways moving progressively the torch from striking Perform cutting so that the point of striking remains in the left over plate Release the trigger to cancel the cutting arc If the cut is not forming correctly Ö cutting speed is too high Ö replace the ...

Страница 18: ... by 10 ref SA 0408 2262 Ö 1 protective casingTI 100 regular cut ref SA 0408 2405 Ö 2 protective casing TN regular cut ref SA 0408 2267 Ö 3 pad regular cut selled by 5 ref SA 0408 2053 Ö 1 mixed key for torch ref SA 0408 2035 Kit CITOARC AP 225 ref SA 8573 2600 is comprised of Ö 5 electrodes HF selled by 5 ref SA 0408 2404 Ö 5 nozzles 1 2 selled by 10 ref SA 0408 2262 Ö 5 nozzles 1 0 selled by 10 r...

Страница 19: ...C INSTRUCTIONS FOR USE CITOARC AP 217 AP 225 C 17 ...

Страница 20: ...rom the electricity mains 1 MAINTENANCE OF THE CITOARC AP 217 AP 225 Periodically depending on the use to which the set is put inspect cleanliness of the CITOARC AP 217 AP 225 electrical and gas connections air filter regulator For all operation Remove the screw from the cover with a 10mm wrench Remove the 2 slings attachment Remove the roof ...

Страница 21: ...crewed in press the reset button Disconnect the torch check on ohmmeter that R is f between the electrode and the nozzle otherwise change the torch THE PILOT ARC DOES NOT WORK PROPERLY U The compressed air pressure is too high U No HF emission U No off load voltage Check that 5 bars P 6 bars After having checked the power supply and the fuse on the HF card check that one second after pushing the t...

Страница 22: ...0 6017 75 60 thermal protector 14 EV1 x x SA 0036 0015 24V 2 5 solenoid valve 15 x x SA 0036 2004 Pressure switch 16 x x SA 0036 5006 Air regulator filter F1 x x SA 0020 0050 Auxiliary 2A fuse F2 F3 x x SA 0020 0008 3A cycle card fuse F4 x x SA 0020 0018 2A HF card fuse Power compartment 17 MV1 x x SA 0010 1541 Fan motor 18 x x SA 0340 3371 300 propeller 19 PD1 x x SA 0018 2023 60 A 1200 three pha...

Страница 23: ...D MAINTENANCE CITOARC AP 217 AP 225 D 21 CITOARC AP 217 CITOARC AP 225 13 17 8 10 11 1 3 2 1 3 7 7 18 23 20 12 19 22 21 14 15 16 9 4 4 5 5 6 6 ...

Страница 24: ...D MAINTENANCE D 22 CITOARC AP 217 AP 225 4 ELECTRICAL DIAGRAMS See diagram opposite ...

Страница 25: ...D MAINTENANCE CITOARC AP 217 AP 225 D 23 5 INSTALLATION OF COMPONENTS ...

Страница 26: ...3 5 2 B4 46 47 48 244 243 241 245 242 BP1 J1 47A 46A 6 4 EV1 3 1 3 4 6 3 L2 100 CITOARC AP 217 INDICE DATE MOTIF A 19 11 99 CHANGEMENT DE COULEUR CABLE BLINDE 1ST CASE RED ANODE LEDS REGISTER 2ND CASE YELLOW ANODE BLUE CATHODE YELLOW CATHODE ELECTRODE NOZZLE WORKPIECE B L U E Y E L L O W INSIDE THE TORCH TRIGGER CONTACT TORCH TIP CONTACT RESET FAULT red THERMAL yellow PRESSURE ON green SOLENOID VA...

Страница 27: ...47 48 245 242 241 243 244 BP1 46A 47A J1 EV1 63 64 3 1 3 4 4X4MM2 WIRE CITOARC AP 225 INDICE DATE MOTIF A 19 11 99 CHANGEMENT DE COULEUR CABLE BLINDE B 11 01 01 AJOUT ECRETEUR ECR1 ECR2 ECR3 ET RESISTANCE R5 33K 1ST CASE RED ANODE LEDS REGISTER 2ND CASE YELLOW ANODE BLUE CATHODE YELLOW CATHODE ELECTRODE NOZZLE WORKPIECE RESET FAULT red THERMAL yellow PRESSURE ON green INSIDE THE TORCH TRIGGER CONT...