1.3.5 Storage of Installation Parts / Spare Parts
If the pump / pump aggregate is to be temporarily stored prior to mounting into
the installation / machine, then it must be kept in the original packing.
The storage of the pump / pump aggregate or separate parts must satisfy the
following conditions:
15 to 25 °C
▪
Ambient temperature:
max. 60 %
▪
Rel. air humidity:
Pumps / pump aggregate that have been installed but not yet commissioned are
subject to the same conditions.
If the pump is stored, the inlet must be filled with a low-viscosity mineral oil. Filling
is to occur while the drive shaft is slowly rotated in the prescribed direction of ro-
tation, until the medium can be seen to flow out of the outlet openings. Next, seal
the inlet and outlet holes and the flushing holes (if present), using the appropriate
protective plugs.
The pump body must in all cases be greased using a resin
‐
free preservation oil
or similar product.