The connection of the hoses to the
pump is realized by hose fittings. If
these are not included in the scope
of delivery, you can order them from
Barmag. In case of client-procure-
ment, only use VA-fittings (stainless
austenitic steels). If using brass fit-
tings, corrosion may occur. If using
nickel-plated brass fittings, the
nickel coat may spall. Both may
cause a pump failure.
▪
Before pushing the hoses into the joint, they must have been cut neat and
straight and must not be squeezed.
▪
The hub of the pump-drive clutch is
to be mounted onto the pump shaft
smoothly and without force. No axial
forces may act on the pump shaft
when mounting the hub as these
would damage internal pump parts.
1.3.4 Disassembly procedure
DANGER
▶
Before the pump is removed from the line / machine or the shaft seal is
disassembled, ensure that all connecting lines are depressurized and
shut off. The drive motor must be de-energized and protected against
unauthorized restart!
GF
Spin-finish pump
Translation of the assembly instructions, V16
10/2022 1-007-3296
TDD-00019389
6
1 Mounting instructions