Operating Instructions and Parts Manual 

25245

NO CONTACT INFRARED 

THERMOMETER

10/18

2018 OEMTOOLS

Emissive:

Most organic materials and painted or oxidized 
surfaces have an emissive of 0.95 (pre-set in the unit). 
Inaccurate readings will result from measuring shiny 
or polished metal surfaces. To compensate, cover the 
target surface with masking tape or flat black paint. 
Measure the tape or painted surface when the tape 
or painted surface reach the same temperature as the 
material underneath. 
 

Operating: 

1.  

Operating the unit:

 

 1) Make sure the 9 volt battery is inserted correctly.

 

2) Press the trigger to turn on the unit.

 

3) Aim at the target surface and pull the trigger,  

 

  then temperature will be shown on the LCD.  

 

  This unit is equipped with a laser, which is only  

 

  used for aiming.

2.      

Locating a Hot Spot:

 

To find a hot spot, aim the thermometer outside  

 

of interest, and then scan across with an up and  

 

down motion until you locate the hot spot.  

 

(Figure Below)

LCD display & buttons: 

1.  

LCD display: 

 

a. Data hold icon

 

b. Scanning icon

 

c. Laser on icon

 

d. Backlight on icon

 

e. Battery power icon

 

f.  Temperature unit

 

g. Temperature reading

2.  

Buttons:

 

1) Trigger: When pressing the trigger, LCD display  

 

  reading with SCAN icon. Release the trigger,  

 

  display reading with HOLD icon for 7 seconds  

 

  (approx). Built-in 7 seconds auto power off  

   function. 
 

2) Laser on/off button

 

3) Celsius/Fahrenheit switch button

 

4) Back light on/off button: When backlight is  

 

  on, any operations will activate the backlight for  

 

  7 seconds.

Maintenance

1.  

Lens Cleaning

 

Blow off loose particles using clean compressed  

 

air. Gently brush remaining debris away with a  

 

moist cotton swab. The swab may be moistened  

 

with water. 

2.  

Case cleaning: 

 

Clean the case with a damp sponge/cloth and  

 

mild soap. 

NOTE:

 

1) Do not use solvent to clean plastic lens.

 

2) Do not submerge the unit in water.

 

Made In China

Содержание 25245

Страница 1: ...72 customerservice oem tools com NO CONTACT INFRARED THERMOMETER The following safety information is provided as a guideline to help you operate your Infrared Thermometer under the safest possible conditions Any tool or piece of equipment can be potentially dangerous to use when safety or safe handling instructions are not known or not followed The following safety instructions are to provide the ...

Страница 2: ...other jewelry may present a potential hazard when operating this tool Keep all apparel clear of the tool 7 Don t overreach Keep proper footing and balance at all times when operating this tool 8 Check for damage Check your tool regularly If part of the tool is damaged it should be carefully inspected to make sure that it can perform its intended function correctly If in doubt the part should be re...

Страница 3: ...ator must understand that common sense and caution are factors which cannot be built into this product but must be supplied by the operator 27 For safety purposes and the prevention of damage to expensive components it is advised that the user have an understanding of basic automotive repair and a working knowledge of automotive systems 28 We believe the information contained herein to be reliable...

Страница 4: ...he unit on or near objects of high temperature Distance to spot size When taking a measurement pay attention to the distance to spot size As the distance D from the target surface increases the spot size S of the area measured by the unit gets larger The distance to spot size of the unit is 12 1 This unit is equipped with a laser which is used for aiming Field of view Make sure the target is large...

Страница 5: ...t spot aim the thermometer outside of interest and then scan across with an up and down motion until you locate the hot spot Figure Below LCD display buttons 1 LCD display a Data hold icon b Scanning icon c Laser on icon d Backlight on icon e Battery power icon f Temperature unit g Temperature reading 2 Buttons 1 Trigger When pressing the trigger LCD display reading with SCAN icon Release the trig...

Страница 6: ...s This warranty does not cover bits blades files batteries or calibration We recommend that you maintain your tools and sharpen or replace blades bits files and batteries as necessary OEMTOOLS reserves the right to makes any changes in construction or design at any time without any obligation in incorporating such changes to tools or equipment previously sold OEMTOOLS makes every effort to assure ...

Отзывы: