background image

3

Operating Instructions and Parts Manual 

23976/23977

12/18

2018 OEMTOOLS

3 SPEED EVAPORATIVE COOLER

SAFETY INFORMATION

READ AND SAVE THESE INSTRUCTIONS

WARNING

:

1.  Unplug the evaporative cooler before moving it 

or performing maintenance. DO NOT touch the 

evaporative cooler when your hands are wet.

2.  Those who are not qualified electricians should not 

disassemble, repair or rebuild the evaporative cooler.

3.  Unplug the evaporative cooler when it is not in use.

4.  DO NOT unplug the evaporative cooler by holding the 

cable cord. Unplug by holding the plug.

5.  DO NOT use the evaporative cooler when there is 

damage to the cable cord or plug.

6.  Avoid the use of extension cords when possible. 

Ensure that they are UL listed if they must be used. DO 

NOT use a single extension cord to operate more than 

one evaporative cooler. DO NOT plug the evaporative 

cooler into any other cord-connected device (power 

strip, surge protector, multiple outlet adapters, etc.).

7.  DO NOT use the evaporative cooler close to any fire or 

heat source.

8.  DO NOT insert your hand or other objects into the rear 

housing when the blade is moving.

9.  To reduce the risk of fire or electric shock, DO NOT 

use this evaporative cooler with any solid-state speed 

control device.

10. DO NOT operate any evaporative cooler with a 

damaged cord or plug. Discard the evaporative 

cooler or return to an authorized service facility for 

examination and/or repair. 

11. DO NOT run cord under carpeting. DO NOT cover cord 

with throw rugs, runners or similar coverings. DO NOT 

route cord under furniture or appliances. Arrange cord 

away from traffic area and where it will not be tripped 

over. 

12. DO NOT use if electrical cord is frayed or bent.

13. DO NOT immerse the evaporative cooler in water.

14. Confirm the rear panel is attached before operating.

15. This evaporative cooler is not intended for use by 

people (including children) with reduced physical, 

sensory or mental capabilities or lack of experience and 

knowledge unless they have been given supervision or 

instructions concerning use of the evaporative cooler 

by a person responsible for their safety. Supervise 

children to ensure they do not play with the evaporative 

cooler.

16. Always place the evaporative cooler on a stable, flat, 

level surface when operating, to avoid the chance of 

the evaporative cooler overturning.

17. To reduce the risk of fire or electrical shock, DO NOT 

expose electrical connections to water. 

18. DO NOT touch electrically live components. 

19. Adequate ventilation is required.

ASSEMBLY INSTRUCTIONS

Evaporative coolers are pre-assembled and ready to 

operate. Simply remove the packaging and then carefully 

remove the unit from the box. Install the casters. 

Casters 

are located in the compartment on the bottom of the 

cooler. Lock the 2 locking wheels before filling and turning 

on fan to keep the cooler from moving from the air velocity.

Lay the cooler down.

Unscrew the two screws, 

remove the bottom panel.

Take out: Casters (4)
Screws (16)
Garden Hose adapter (1)

Install 4 Casters.

NOTE

:

 

The media pad will have a slight odor when it is 

new. This is normal. It will dissipate after a period of time 

depending on the use time. Draining the tank often during 

the break-in period will help speed this up.

OPERATING INSTRUCTIONS

1.  Your cooler must be positioned in front of an open 

window or door if it is to operate effectively.

2.  Always ensure that there is another open window or 

door through which the air can exhaust from the room.

3.  Ensure the filter is kept clean throughout the summer 

season.

4.  At the end of each day, run your cooler on FAN ONLY 

for 30 minutes to dry out the filter.

Содержание 23976

Страница 1: ...the equipment understands and follows these safety instructions as well Operating Instructions and Parts Manual 23976 23977 FOR CUSTOMER SERVICE Technical Question CALL 1 866 458 2472 customerservice...

Страница 2: ...olers DO NOT USE until repaired 13 Use only accessories that are recommended by the manufacturer for your model Accessories that may be suitable for one tool may become hazardous when used on another...

Страница 3: ...erse the evaporative cooler in water 14 Confirm the rear panel is attached before operating 15 This evaporative cooler is not intended for use by people including children with reduced physical sensor...

Страница 4: ...mum 50 PSI If valve is overcome install a pressure reducer 25 PSI on nipple first It can be obtained at hardware stores in the Irrigation section Hose bib needs only be cracked open slightly to supply...

Страница 5: ...re this procedure The submersible pump is mounted inside the tank to the bottom with a retention bracket While you are cleaning the cooler the pump may be removed and the strainer cap on the bottom of...

Страница 6: ...or 6037051 6061051 3 Rigid Media Set CP370 CP610 4 Control Board 6037069 6037069 5 Casters 6036061 6060061 6 Casters w lock 6036062 6060062 7 Fan Blade 6037052 6061052 8 Float Valve 6018058 6018058 9...

Страница 7: ...slow at start up 3b 1 Replace motor capacitor 4 Louver does not operate 4 1 Louver does not move Move swing switch position to ON 4 2 Check Oscillator motor for proper placement and operation 5 Water...

Страница 8: ...ce blades bits files and batteries as necessary OEMTOOLS reserves the right to makes any changes in construction or design at any time without any obligation in incorporating such changes to tools or...