14,700 CFM VARIABLE SPEED
EVAPORATIVE COOLER
WARNING
: Water Inlet pressure should not exceed
50 PSI. Higher pressure may lead to product failure and
property damage.
OPTIONAL
: For cooler air, ice cubes may be added to the Ice
Cube Input located at the rear of the cooler.
4. Switch the Pump to ON. Allow to run for 2-3 minutes to
saturate the Cooling Pads with water.
5. Switch the Fan to ON. Slowly increase the speed of the
fan using the Fan Speed Dial.
6. To oscillate airflow, switch the Swing Setting to ON.
SHUTDOWN INSTRUCTIONS
1. Close the water source.
2. After the Water Tank has emptied, switch the Pump to OFF.
NOTE:
See Draining Instructions if the Water Tank is not
empty.
3. At the end of each day of use, allow the fan to run for
about 20 minutes to dry the Cooling Pads.
4. Slowly decrease the fan speed to 0 on the Fan Speed Dial.
5. Switch the Fan to OFF.
6. Unplug the Power Cord from the power source.
EMERGENCY STOP INSTRUCTIONS
IMPORTANT:
If any malfunction or circumstance that alters
the operating performance or safety of the Evaporative Cooler
occurs, DEPRESS the Emergency Stop Button immediately.
Unplug the Power Cord from the Power Source.
WARNING
: If this unit is operating abnormally in any way,
DEPRESS the Emergency Stop Button immediately. Abnormal
operation may manifest visibly, or as irregular noises or
burning smells.
1. Once the fan has stopped, inspect the unit for any
noticeable and overt causes of malfunction or failure.
2. DO NOT attempt maintenance or repair outside
of cleaning practices described in the Product
Maintenance section of this manual. Contact qualified
personnel before attempting use.
DRAINING INSTRUCTIONS
1. It is recommended that the Water Tank be emptied at the
end of each day of use.
a. Manual Drain
i. Open valve located at the bottom of the unit.
AND/OR
b. Automatic Drain
i. Rotate the lever on the Automatic Drain Valve.
ii. Switch the Pump to ON.
iii. Switch the Pump to OFF once the water has been
evacuated.
2. To optimize the draining process, use the Automatic Drain
to drain the majority of the water. Once the water has
been evacuated, open the Manual Drain to empty any
excess water left at the bottom of the Water Tank.
STORAGE
Store the Evaporative Cooler in an upright position and in
a clean, dry area. DO NOT store near flammable items or
open flames.
PRODUCT MAINTENANCE
WARNING
: DO NOT use water to clean the Fan, Electrical
Components or Control Panel.
WARNING
: Unplug this unit before performing product
maintenance.
1. Dirt and debris will settle at the bottom of the Water Tank.
To optimize performance, it is recommended that the
Water Tank is cleaned monthly.
2. To maintain high air quality, it is recommended that the
water is flushed from the Water Tank daily.
3. Ensure cooling pads are dry and clear of dirt/debris prior
to storage.
DISPOSAL
At the end of the useful life of the OEMTOOLS
™
14,700
CFM Variable Speed Evaporative Cooler, dispose of the
components in accordance with all federal, state and
local regulations.