12 

 

How to order? 

 
PCA-20-XXXX-YY or PCA-25-XXXX-PD, where: 

-

 

XXXX means V

MAX

 voltage (user selectable in the range of 300V-1500V, 

higher output voltages are available upon request). We would recommend to 
pick V

MAX

 as close as possible to your operating voltage in order to utilize 

completely the output power of the device 

-

 

YY means either CD (complete discharge modification) or PD (partial 
discharge modification); if YY is not specified PD modification will be 
supplied 

 
Examples (the most popular modifications): 

P/N 

Description 

Certificates 

PCA-20-300V-PD 

110-240VAC input, 2000W/300V output, partial discharge 

On demand 

PCA-20-500V-PD 

110-240VAC input, 2000W/500V output, partial discharge 

IEC 60601-1:2005 + 

A1: 2012 

IEC 60601-1-2:2014 

PCA-20-700V-PD 

110-240VAC input, 2000W/700V output, partial discharge 

On demand 

PCA-20-800V-PD 

110-240VAC input, 2000W/800V output, partial discharge 

IEC 60601-1:2005 + 

A1: 2012 

IEC 60601-1-2:2014 

PCA-20-1000V-PD 

110-240VAC input, 2000W/1000V output, partial discharge 

IEC 60601-1:2005 + 

A1: 2012 

IEC 60601-1-2:2014 

PCA-20-1500V-PD 

110-240VAC input, 2000W/1500V output, partial discharge 

On demand 

 
PCA-25-350V-PD 

200-240VAC input, 2500W/350V output, partial discharge 

IEC 60601-1:2005 + 

A1: 2012 

 
PCA-20-700V-CD 

110-240VAC input, 2000J/s /700V output, complete discharge 

On demand 

PCA-20-1000V-CD 

110-240VAC input, 2000J/s /1000V output, complete discharge 

On demand 

PCA-20-1500V-CD 

110-240VAC input, 2000J/s /1500V output, complete discharge 

On demand 

Other modifications are available on request. 
 
 

Environmental protection 

 
Module should not be disposed of with household waste.  
Please, dispose the module in accordance with the regulations for electronic waste 
management in your country. 
 
 

Name and address of the manufacturer 

 
OEM Tech O.O.O. 
Odoevskogo 129 
220018 Minsk, Belarus 

 

Содержание PCA-20

Страница 1: ...rning This equipment may be dangerous Please read the entire user manual carefully before using the product Important note Module is sensitive to the reverse polarity applied to the output If you aren...

Страница 2: ...ION 4 COOLING 4 APPEARANCE 4 CONNECTORS PINS INTERFACE SIGNALS 5 INSTALLATION 8 OPERATIONS 8 FAULTS 8 SPECIFICATIONS 9 DIMENSIONAL DRAWING 11 HOW TO ORDER 12 ENVIRONMENTAL PROTECTION 12 NAME AND ADDRE...

Страница 3: ...d to open the device Warning The equipment is not suitable for use in presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide Explanation of symbols Symbol Description Refe...

Страница 4: ...level VMAX could be choosen from 300V to 1500V at the moment of order Higher output voltages are available upon request By default modules are optimized for partial discharge applications Complete di...

Страница 5: ...Usage of longer cables may result in increased electromagnetic emission and or decreased electromagnetic immunity of the equipment and correspondingly in improper operation MOUNTING M4 thread x4 Modul...

Страница 6: ...imum output current 40mA 11 orange 5 V This pin provides 5V DC that may be used for status LEDs etc Maximum output current 40mA 12 18 N C 13 white black mark Overtemp Fault Indicator 2 This pin is pul...

Страница 7: ...5mA Rout 1kOhm 19 white red mark Fault Indicator This pin is pulled to ground when some failure occurs In this case the high voltage output will be also disabled Failures output short circuit overvol...

Страница 8: ...starts 4 Enable the high voltage output PIN7 of INTERFACE 5 After operations disable the high voltage output then disconnect module from the mains Faults Fault Cause of the fault Troubleshooting Overv...

Страница 9: ...ifications can be achieved in regime 70 100 of VMAX rated input voltage 25 C 2000W 2500W Nominal output power complete discharge modifications can be achieved in regime 10 100 of VMAX rated input volt...

Страница 10: ...urrent 200 A Isolations see Means of protections section Protections from open circuit from short circuit from overheating from overvoltage Cooling Forced air build in fan Environment Operation temper...

Страница 11: ...11 Dimensional drawing...

Страница 12: ...rge On demand PCA 20 800V PD 110 240VAC input 2000W 800V output partial discharge IEC 60601 1 2005 A1 2012 IEC 60601 1 2 2014 PCA 20 1000V PD 110 240VAC input 2000W 1000V output partial discharge IEC...

Страница 13: ...1000 4 3 List of frequencies Table 9 from 9 V m up to 28 V m PM 18 Hz or 217 Hz FM 1 kHz Complies Immunity from Electrical Fast transient EFT IEC 61000 4 4 2 kV on 230 VAC Tr Th 5 50 ns 100 kHz Compli...

Страница 14: ...king voltage depends on modification Input to input opposite polarity before fuses 1x MOOP 340Vpk Output to chassis Output negative is intentionally connected to the chassis Mains part to chassis 1x M...

Отзывы: