Connectors / Pins / Interface signals
INPUT:
Blue
wires (2pcs) – AC input (110-240VAC 50/60Hz)
HV OUTPUT:
Red
wire – HV OUTPUT positive
Black
wire – HV OUTPUT negative
Cable length warning
Despite the lengths of all cables can be customized on request,
we recommend to keep length of HV OUTPUT and INPUT cables as short as
possible (max 30-50cm). Usage of longer cables may result in increased
electromagnetic emission and/or decreased electromagnetic immunity of the
equipment and, correspondingly, in improper operation.
MOUNTING:
M4 thread (x4)
Module should be mounted using these threads. Max. screw depth is 4mm.
GROUND:
M4 thread
Module should be grounded using this thread. Max. screw depth is 6mm.
Grounding should be done before connecting the module to the mains.
Grounding policy
HV OUTPUT negative and INTERFACE return are internally connected to the
device ground (chassis). Other grounding policies are available on request.