Safety
Warning!
This equipment produces high voltages that can be very dangerous.
Be careful around the equipment.
Assemble the entire setup before powering up the device.
•
Power supply enclosure is to be protectively grounded via provided grounding stud.
•
Use low voltage power supply with DC output galvanically insulated from AC input
(insulation strength 4000VAC, 2500VAC or 1500VAC is selected in dependence on your
application)
•
Do not connect / disconnect output cables while driver is turned on
•
Do not operate with disconnected load
•
Avoid casual contacts of personnel with output cables and with the load
•
Do not turn the power supply on if it was already damaged with water, chemicals,
mechanical or electrical shock
•
Do not self-repair the power supply, there are no user-serviceable parts inside
Operations
1
Ensure 24V DC (48V DC) power supply is off
2
Connect PBZ-300 (PBZ-500) to the load and to 24V DC (48V DC)
power supply. Do not apply DC power until the setup is completely
assembled
3
Disable
PBZ-300 (PBZ-500) (pin 7 of Interface)
4
Set HV Program to 0V (pins 3 and 4 of Interface)
5
Apply 24V DC (48V DC) power to PBZ-300 (PBZ-500)
6
Set HV Program to the desired value (pins 3 and 4 of Interface)
7
Enable
PBZ-300 (pin 7 of Interface)