NOTCH
THRESHOLD
Threshold value (in percent) for the recognition of the presence of notch by the notch
sensor:
0.5V 2.0V
D
3.5V
1.0V 2.5V
4.0V
1.5V 3.0V
4.5V
NOTE:
If the “Notch Alignment” parameter is disabled, this parameter is not printed.
NOTCH
DISTANCE
“Notch Distance” is the minimum distance (in mm) between the upper edge of ticket
and the notch (see chapter 10).
The numeric value of the distance is made up with the following three parameters for
the setting of three digits:
NOTCH DISTANCE [mm x 100]
Setting the digit for hundreds:
0
D
2 4
6 8
1 3 5 7 9
NOTCH DISTANCE [mm x 10]
Setting the digit for tens:
0
D
2 4
6 8
1 3 5 7 9
NOTCH DISTANCE [mm x 1]
Setting the digit for units:
0
D
2 4
6 8
1 3 5 7 9
NOTE:
For example, to set the notch distance to 15 mm, modify the parameters as follows:
Notch Distance [mm x 100] = 0
Notch Distance [mm x 10] = 1
Notch Distance [mm x 1]
= 5
NOTE:
If the “Notch Alignment” parameter is disabled, the parameters for the “Notch Distance” are
not printed.
SHORT TICKET (<150mm)
This parameter allows the ticket management:
Disabled
D
=
no check
Enabled =
it is possible to manage tickets with length less than the distance
between the notch sensor and the printing line (160mm)
DENSITY
Adjusting the printing density:
-50% -12% +25%
-37% 0
D
+37%
-25% +12% +50%
5. CONFIGURATION
User manual
KPM216HII 43
Содержание KPM216HII
Страница 1: ...OEM Commands manual 77200000002000 KPM216HII KPM216HII USER MANUAL...
Страница 2: ......
Страница 4: ......
Страница 8: ...1 INTRODUCTION 8 KPM216HII User manual...
Страница 16: ...2 DESCRIPTION 16 KPM216HII User manual...
Страница 49: ...5 Insert the new paper see previous paragraphs 6 MAINTENANCE User manual KPM216HII 49...
Страница 60: ...6 MAINTENANCE 60 KPM216HII User manual...
Страница 74: ...7 SPECIFICATIONS 74 KPM216HII User manual...
Страница 76: ...8 CONSUMABLES 76 KPM216HII User manual...
Страница 86: ...10 ALIGNMENT 86 KPM216HII User manual...