![OEM DC BWA-SS-12 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/oem/dc-bwa-ss-12/dc-bwa-ss-12_installation-and-maintenance-instructions-manual_724551045.webp)
43
Control
Alarm Messages
The cause of alarm ‘WARM WATER TEMP.’ could be:
1. The connection of water tank temperature sensor was loose;
2. The water tank temperature sensor was broken;
How to do:
1. Find the connection and make sure it is fine;
2. As per resistance table of the sensor, please measure the sensor’s resistance, to judge the
sensor was good or bad; replace a new one if the sensor get problem.
The cause of alarm ‘FEEDLINE TEMP.’ could be:
1. The connection of feed water temperature sensor was loose;
2. The feed water temperature sensor was broken;
How to do:
1. Find the connection and make sure it is fine;
2. As per resistance table of the sensor, please measure the sensor’s resistance, to judge the
sensor was good or bad; replace a new one if the sensor get problem.
The cause of alarm ‘RETURN TEMP.’ could be:
1. The connection of return water temperature sensor was loose;
2. The return water temperature sensor was broken;
How to do:
1. Find the connection and make sure it is fine;
2. As per resistance table of the sensor, please measure the sensor’s resistance, to judge the
sensor was good or bad; replace a new one if the sensor get problem.
The cause of alarm ‘PIPE TEMP.’ could be:
1. The connection of pipe temperature sensor (on evaporator, for defrosting) was loose;
2. The pipe temperature sensor was broken;
How to do:
1. Find the connection and make sure it is fine;
2. As per resistance table of the sensor, please measure the sensor’s resistance, to judge the
sensor was good or bad; replace a new one if the sensor get problem.
The cause of alarm ‘OUTDOOR TEMP.’ could be:
1. The connection of outdoor ambient temperature sensor was loose;
2. The outdoor ambient temperature sensor was broken;
How to do:
1. Find the connection and make sure it is fine;
2. As per resistance table of the sensor, please measure the sensor’s resistance, to judge the
sensor was good or bad; replace a new one if the sensor get problem.