Odorox Decon Скачать руководство пользователя страница 3

ENGLISH

PLEASE READ AND SAVE 
THESE IMPORTANT SAFETY  
INSTRUCTIONS 

IMPORTANT SAFEGUARDS

 

When  using  electrical  equipment,  basic  safety 

precautions should always be followed to reduce 

the  risk  of  fire,  electric  shock,  and  injury  to 

persons, including the following: 

• Read all instructions before using this Hydroxyl 

Generator. 

• To avoid fire or shock hazard, plug the equipment 

directly into a 120V AC electrical outlet. 

•  If  the  generator  is  covered  by  a  bag  when 

shipped: Remove plastic bag before use. 

• Keep the cord out of heavy traffic areas. To avoid 

fire hazard, NEVER put the cord under rugs, near 

heat registers, radiators, stoves, or heaters. 

• To protect against electrical hazards, DO NOT 

immerse in water or other liquids. Do not use near 

water. 

•  Close  supervision  is  necessary  when  any 

generator is used by or near children, or disabled 

persons. 

• WARNING! Always unplug the generator before 

moving it, cleaning, or whenever the generator is 

not  in  use.  Be  sure  to  pull  by  the  plug  and  not 

the cord. 

•  NEVER  drop  or  insert  any  object  into  any 

openings. 

• DO NOT use an extension cord. Doing so can 

create potential safety hazards. 

• DO NOT operate any generator with a damaged 

cord or plug, if motor fan fails to rotate, after the 

generator malfunctions, or if it has been dropped 

or  damaged  in  any  manner.  Return  generator 

to  manufacturer  or  authorized  repair  facility  for 

examination, electrical or mechanical adjustment, 

or repair. 

• Use generator only for intended use as described 

in this manual. Any other use not recommended by 

the manufacturer may cause fire, electric shock, 

or injury to persons. The use of attachments not 

recommended may cause hazards. 

• DO NOT use outdoors. 

• NEVER block the air openings, grills/outlets or 

place on a soft surface such as a bed or sofa, as 

this could cause the unit to tip over, blocking the 

Air Intake Opening/Grill. 

• Keep unit away from heated surfaces and open 

flames. 

•  CAUTION:    For  General  Ventilating  Use  Only.  

Do Not Use to Exhaust Hazardous or Explosive 

Materials and Vapors.

• DO NOT attempt to repair or adjust any electrical 

or mechanical functions on this unit. Doing so will 

void your warranty. The inside of the unit contains 

no user serviceable parts. All servicing should be 

performed by qualified personnel only. 

• WARNING! To reduce the risk of fire or electric 

shock, DO NOT use this generator with any  solid-

state speed control device. 

• DO NOT place anything on top of generator. 

• DO NOT plug the cord in with wet hands: electric 

shock could result. 

• NEVER use detergents, gasoline, glass cleaner, 

furniture polish, paint thinner or other household 

solvents to clean any part of the generator. 

•  To  avoid  a  shock,  plug  the  unit’s  three-prong 

plug into a grounded outlet. 

• DO NOT under any circumstances cut or remove 

the  third  (Ground)  prong  from  power  cord.  For 

personal  safety,  this  generator  must  be  properly 

grounded. 

WARNING!

IMPORTANT SAFETY INFORMATION. READ ALL 
INSTRUCTIONS BEFORE USING.

 

Use this Hydroxyl Generator only for its intended 

purpose as described in this Owner’s Manual. 

1

Содержание Decon

Страница 1: ...Decon Scrubber Owner s Manual Serial ____________________ REV0001111209 TM...

Страница 2: ...S Warning 1 Operating the Decon Scrubber 2 System Placement 4 Caring for your Decon Scrubber 5 Cleaning Instructions 6 Optic Replacement Instructions 7 Filter Replacement Instructions 10 Specification...

Страница 3: ...nt or repair Use generator only for intended use as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons The use of attachments...

Страница 4: ...r of hydroxyl generating optics in operation 4 Hour Meter Quartz non reversible indicator of accumulated hours of use 5 Minihelic Gauge Gauge which senses the static pressure through the 4 inch filter...

Страница 5: ...n Once the MAIN POWER switch is on the fan speed can be controlled by rotating the FAN SPEED knob clockwise to increase the speed or counter clockwise to decrease the speed PROCESSOR SWITCH The Decon...

Страница 6: ...sition for the system You should position the system as per Figure 1 for efficient decontami nation If you are using two or more systems place them so they blow into the contami nated area to create a...

Страница 7: ...exterior OPTIC CLEANING Cleaning of the optics is recommended to maintain peak processing efficiency Fingerprints smudg es dirt dust particles etc will interfere with the hydroxyl production and shoul...

Страница 8: ...ews and gently pulling off panel Step 6 Use compressed air to blow out all compartments Step 7 Using a cleaning solution of 10 Isopropyl Alcohol Isopropyl Alcohol strength of 70 or 90 and 90 filtered...

Страница 9: ...e front side side opposite handle NOTE Ensure unit is set on a stable non scratch surface CAUTION Unit is heavy Use proper lifting techniques and at least two people to avoid injury Step 4 Remove Phil...

Страница 10: ...le pulling from the optic base Step 7 Gently pull optic from three optic supports Note Do not put any pressure on the side of the optic without support Step 8 Gently install new optic by pressing into...

Страница 11: ...onnect optic connector Optic connector is keyed and will only connect in one direction If unable to connect optic base with optic connector rotate connector 180 and try again Step 10 Re install bottom...

Страница 12: ...the phillips quarter turn fastener counter clockwise on the main filter door Step 4 Swing top of main filter door down Step 5 Remove 4 inch filter Step 6 Install new 4 inch filter NOTE Ensure proper...

Страница 13: ...ter door or push and turn the phillips Star quarter turn fastener counter clockwise Step 4 Pull the top of the pre filter door out and lift off Step 5 Remove 2 inch filter Step 6 Install new 2 inch fi...

Страница 14: ...the bottom of the door while the top gets pushed in place Step 9 Reinstall Phillips Star screw previously removed or push and turn the phillips Star quarter turn fastener clockwise ENGLISH FILTER REPL...

Страница 15: ...artz Hour Meter WARRANTY HGI Industries Inc warrants that this Decon Scrubber excluding spare parts and consumables shall be free from defects in workmanship or materials for a period of one 1 year fr...

Страница 16: ...ion and maintenance of your Odorox product please contact your local Odorox distributor Odorox Hydroxyl Generators are proudly manufactured in the USA Copyright 2011 HGI Industries Incorporated Odorox...