background image

Pag. 6 

9

 

BATTERY SETUP MENU 

 

Display 

Description 

STDBY 

Time in minute after that the display will be set in standby status ( If = 0 standby 
not active ) 

STATO 

If set to ON it means that the indicator is connected to battery so it is possible to 
display the status of the battery charge.  

 
During  the  standby  status,  the  scale  is  not  turned  off;  to  return  to  normal  weight  indication, 
press a key or move the plate of the scale. 
In  order  to  display  the  status  of  the  battery  charge,  press  the  ESC  key.  The  indication  is  a 
value from 0 to 5; the maximum value of charge is 6,2 V corresponding to 5. 
If  the  charge  of  the  battery  is  lower  than  a  safe  value,  the  display  will  show  the  indication 
“BATT” and after a time, it will automatically turned off. 

 

10

 

 HIGH PRECISION WEIGHT DISPLAY 

 

The high precision corresponding value of the current weight will be indicated on the display. 
Press ESC to exit. 

 

11

 

EXTERNAL CONNECTIONS 

 

 

 

 

J1 : 

Load Cell Connection 

 

 

J2 : 

RS232 Serial Connection 

1

 

Shield  

 

 

 

 

Rx 

2

 

+ Excitation   

 

 

 

Tx 

3

 

+ Signal 

 

 

 

 

Gnd 

4

 

– Signal 

5

 

+ Reference   

 

 

J3 : 

Power supplying connection

 

6

 

– Reference   

 

 

 

Internal 

7

 

– Excitation   

 

 

 

External 

+ 7,5 V or + 12 Vdc   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание SW23

Страница 1: ...USER MANUAL WEIGHT INDICATOR MOD SW23 USE AND INSTALLATION GUIDE Rel 009_0 0 www odeca it...

Страница 2: ...y battery status Dimension 160 mm x 95 mm x 60 mm Load cell power suppl 5 Vdc 90 mA max 6 load cells da 350 Sensitivit 0 2 V div Linearit 0 01 R O Temperature effect 0 001 R O C Internal resolution 24...

Страница 3: ...o Long press Print Esc Short press Display battery status if status ON Long press OFF SET Short press Tara Long press Numeric Tare 4 LED INDICATORS Led n 1 Center of zero or range1 if multirange is se...

Страница 4: ...sible to set RANGE to ON 6 WEIGHT CALIBRATION After the confirmation of the CALIB function the display will show alternatively the weight value and the CAL indication 6 1 ZERO CALIBRATION Press the ke...

Страница 5: ...nuous weight transmission PC RIC Transmission on PC Request The configuration of the serial RS232 output is Baud Rate 9600 Baud Parity None Bit Dati 8 Bit Stop 1 Transmission Frequency 6 Tx sec The Fr...

Страница 6: ...battery charge press the ESC key The indication is a value from 0 to 5 the maximum value of charge is 6 2 V corresponding to 5 If the charge of the battery is lower than a safe value the display will...

Страница 7: ...12 INTERNAL CONNECTIONS 1 2 3 1 2 3 JP1 JP2 SUPPLY SUPPLY SGND RXD TXD SIGN SIGN REF REF EXCIT EXCIT 3 4 5 6 1011 7 8 9 2 1 JP1 2 3 DEFAULT 1 2 PROGRAMMAZIONE DATI DI TARATURA JP2 2 3 SEMPRE ON 1 2 DE...

Страница 8: ...EMC Directive adopted European Standard EN 55011 EN50082 1 Direttive CEE 73 23 e 93 68 sulla sicurezza elettrica in bassa tensione Norma Europea EN 61010 1 73 23 and 93 68 EU Directives regarding low...

Отзывы: