68
ODB COMPANY
800-446-9823
SKB700
Service Section
figure 5.3a
Review the safety section of this manual before attempt-
ing these procedures.
Once the shaft is in place, lock down the bear-
ings:
Starting with the rear bearing (closest to the
blower housing) install the rear collar on the
blower housing side (figure 5.3b). The rubber
seal should be facing the bearing.
Push the steel collar up to the bearing and make
sure the groove in the collar goes inside the
groove in the bearing.
Tighten the set screw (figure 5.3e).
Install the front locking collar sliding the locking
collar up to the bearing and the turn the collar
clockwise until is slips over the inner ring exten-
sion and engages the eccentric. Turn by hand
until the parts are locked together.
Place a punch or drift in the blind hole in the collar
and strike it sharply to the lock the collar and ring
tightly together (figure 5.3f)
Tighten the set screws with an Allen wrench until
the set screw stops. (figure 5.3g)
Do steps 11-14 for the other bearing also.
Line up the pulleys and tighten the busing.
Re-install the belt guards and impeller as de-
scribed earlier.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
Installing the Drive Bearings, continued:
figure 5.3b
Collar (Item# 8)
Bearing Plate
Set Screw
figure 5.3e
figure 5.3f
figure 5.3g
5.6 Flange Bearing Installation and Removal, cont.
Содержание SKB700
Страница 14: ...14 ODB COMPANY 800 446 9823 SKB700 SAFETY PRECAUTIONS 1 4 Safety Decals Decal Layout for SKB700...
Страница 35: ...35 ODB COMPANY 800 446 9823 SKB700 Operating Section...
Страница 36: ...36 ODB COMPANY 800 446 9823 SKB700 Operating Section...
Страница 37: ...37 ODB COMPANY 800 446 9823 SKB700 Operating Section...
Страница 85: ...85 ODB COMPANY 800 446 9823 SKB700 Service Section Engine Main Harness 5 10 2 Engine Main Harness Enlarged...
Страница 91: ...91 ODB COMPANY 800 446 9823 SKB700 Service Section 5 10 7 Remote Throttle Clutch Wiring Harness...
Страница 99: ...99 ODB COMPANY 800 446 9823 SKB700 Service Section 5 11 8 IQAN Power Switch and E Stop Wiring Diagrams G...
Страница 117: ...117 ODB COMPANY 800 446 9823 SKB700 7 5 Kraft Fluid Drive Group Optional Fluid Drive Coupler Optional...
Страница 118: ...118 ODB COMPANY 800 446 9823 SKB700 7 6 Kraft Fluid Drive Installation Optional Fluid Drive Coupler Optional...
Страница 119: ...119 ODB COMPANY 800 446 9823 SKB700 7 7 Kraft Fluid Drive Breakdown Optional Fluid Drive Coupler Optional...
Страница 138: ...138 ODB COMPANY 800 446 9823 SKB700 INDEX Volt Meter 76 W Water Temperature Sender 82...