5.4 Impeller Installation and Removal
Before removing the blower housing
face remove the negative battery cable to
ensure unit can not be started.
REMOVAL
1. The blower housing face must be removed to gain access to the
impeller. Use an overhead crane or forklift to support the face
while removing.
2. Once the face has been removed, remove the shaft protector
(Fig. 1 or 2).
3. Saturate the shaft and bushing using a penetrating lubricant to
help loosen the bushing. Clean any grease or debris from the
bushing and shaft.
4. Remove the 3 bolts attaching the bushing to the impeller.(Fig.
3) Being careful not to break the bolts. If a set screw is on the
lip of the bushing, loosen it using an allen wrench.(Fig. 4)
5.
Using two of the bolts that were just removed screw those bolts
into the threaded holes on the bushing. Drive the two bolts
into the bushing.(Fig. 5) This will separate the bushing from
the impeller. Alternate from one bolt to the other driving only
about a 1/4” at a time to keep the bushing coming out straight.
It is imperative to keep the bushing straight to remove it.
IMPORTANT: Be sure to drive the bushing out evenly or it will
get in a bind making removal much harder.
6.
If the bushing does not come off using the two bolts, drill and
tap several additional 3/8-16 holes around the bushing. Us
-
ing Grade 8, 3/8-16 - 2 inch bolts, alternately drive the bolts
1/4” at a time to remove the bushing. KEEP THE BUSHING
STRAIGHT while removing.
IMPORTANT: If additional holes were drilled in the bushing, it
can not be reused. It must be be replaced.
7. Once the bushing has been removed use an overhead crane or
other suitable device to help lift the impeller out of the blower
housing.
8. At this point it would be a good idea to inspect the blower
housing liners and blower housing for any damage or wear.
Any damage or wear to the liners should be fixed by replacing
the liners immediately.
Fig. 3
Fig. 4
Fig. 5
Fig. 1
Fig. 2
Direct
Drive
Belt
Drive
Содержание DCL800TM
Страница 16: ...16 ODB Company DCL800TM 1 4 Safety Decals Decal Layout for SCL800TM 24 25 26 27 28 19 20 21 22 23 ...
Страница 35: ...35 ODB Company DCL800TM ...
Страница 36: ...36 ODB Company DCL800TM ...
Страница 37: ...37 ODB Company DCL800TM ...
Страница 78: ...78 ODB Company DCL800TM 5 10 4 Trailer Bed Wiring Harnesses Diagram Exploded Views Follow ...
Страница 79: ...79 ODB Company DCL800TM 5 10 5 Chassis Wiring Harness Diagram ...
Страница 80: ...80 ODB Company DCL800TM 5 10 6 Brake Wiring Harness Diagram ...
Страница 81: ...81 ODB Company DCL800TM 5 10 7 Bed Wiring Harness Diagram ...
Страница 82: ...82 ODB Company DCL800TM 5 10 8 Box Wiring Harness Diagram ...
Страница 85: ...85 ODB Company DCL800TM 5 10 11 Remote Throttle Clutch Wiring Harness ...
Страница 87: ...87 ODB Company DCL800TM 5 20 1 Hoist Hydraulic System 14 and 20CY ...
Страница 88: ...88 ODB Company DCL800TM 5 20 2 Hoist Hydraulic System 25 and 30CY ...
Страница 89: ...89 ODB Company DCL800TM 5 20 3 Hoist Hydraulic System with Parking Jack ...
Страница 98: ...98 ODB Company DCL800TM 6 7 Kubota Common Service Kubota Engines ...
Страница 99: ...99 ODB Company DCL800TM 6 8 Kubota Sheet Metal Group Kubota Engines ...
Страница 100: ...100 ODB Company DCL800TM 6 9 Kubota Air Cleaner Group Kubota Engines ...
Страница 101: ...101 ODB Company DCL800TM 6 10 Kubota Exhuast Component Group Kubota Engines ...
Страница 110: ...110 ODB Company DCL800TM 7 5 Kraft Fluid Drive Group Optional Fluid Drive Coupler Optional ...
Страница 111: ...111 ODB Company DCL800TM 7 6 Kraft Fluid Drive Installation Optional Fluid Drive Coupler Optional ...
Страница 112: ...112 ODB Company DCL800TM 7 7 Kraft Fluid Drive Breakdown Optional Fluid Drive Coupler Optional ...
Страница 144: ...144 ODB Company DCL800TM ...