Ocular IOCAW05C-22S Скачать руководство пользователя страница 5

5

WARNING!

CAUTIONS!

SAFETY INSTRUCTION

Do not install or use the charger near flammable, explosive, harsh,  

or combustible materials, chemicals, or vapors.

Turn off input power at the circuit breaker before installing or maintaining.

Do not use or stop using the charger if it is defective, appears cracked, frayed, broken or other-

wise damaged, or fails to operate.

Do not attempt to open, disassemble, repair, tamper with, or modify the charger.  

The charger is not user serviceable. Contact your installer for any repairs.

Do not use the charger when either you, the vehicle or the charger is exposed to  

severe rain, snow, electrical storm or other inclement weather.

Do not touch the charger sockets with sharp metallic objects,  

such as wire, tools or needles.

Do not put fingers into the charger sockets.

Do not use this charger if the EV charging cable is frayed, has broken insulation,  

or displays any other indication of damage.

Do not use this charger if the enclosure or the EV charging connector is broken, cracked, open, or 

shows any other indication of damage.  

The charger should be installed only by a qualified electrician.

Make sure that the materials used and the installation procedures follow local building codes 

and safety standards.

Incorrect installation and testing of the charger could potentially damage either the vehicle’s 

Battery and/or the charger itself. Any resulting damage is excluded from the warranty for both 

the vehicle and the charger. Do not operate the charger in temperatures outside its operating 

range of -30°C to +50°C.

Ensure that the EV charging cable is positioned properly to the charging sockets.  

Do not use cleaning solvents to clean any of the charger’s components.

Be careful not to damage the circuit board when removing the power entry knock-out.

Содержание IOCAW05C-22S

Страница 1: ...OCULAR IQ COMMERCIAL IOCAW05C 7S 7T IOCAW05C 22S 22T INSTALLATION GUIDE ocularcharging com au sales ocularcharging com au 1300 912 650...

Страница 2: ...er Cable Wiring Step Four Internet Connection Step Five Verify The Installation Step Six Secure Cover READ THIS ENTIRE DOCUMENT BEFORE INSTALLING OR USING THE CHARGER FAILURE TO DO SO OR TO FOLLOW ANY...

Страница 3: ...OCPP 1 6J Charging Connector IEC62196 Type 2 socket or 5m type 2 cable Buttons 1 x Physical Button RFID ISO 14443 A B Display 7 inch LCD Display Network Connectivity Ethernet WLAN optional 4G Cellular...

Страница 4: ...ails about the LCD screen can be found on pages 10 12 The Ocular IQ Commercial charger comes with an inbuilt RFID reader to allow for access control to the charging station The RFID Reader is compatib...

Страница 5: ...ts Do not use this charger if the EV charging cable is frayed has broken insulation or displays any other indication of damage Do not use this charger if the enclosure or the EV charging connector is...

Страница 6: ...Screw M6 12 x 1 Dynabolts x 4 Slotted 6 screwdriver Philips 2 screwdriver Electric drill TURN OFF THE POWER SUPPLY Then follow these steps to install the Charger No Steps 1 2 3 4 5 6 Check box conten...

Страница 7: ...the backplate Fix the EV charger to the backplate with M6 12 screw Step 02 Wall Mounting 01 02 03 INSTALLATION Cross the power wires through the bottom hole Connect the power wires to the terminal bo...

Страница 8: ...ioc XXXXXX and enter default password IOC12345 b Open web based setup page by entering the default IP Address 192 168 10 1 8900 and enter Username admin and Password ioc12345 then click ok No Item 1...

Страница 9: ...r on the charger unit and you should see the LED lights sequentially illuminate green If the LED red light illuminates or flashes refer to the Troubleshooting table on page 11 Check on the screen disp...

Страница 10: ...VSE Connect the charging plug Remove the charging plug Automatic upgrade mode activated Software downloading and upgrading automatically Network upgrade mode Micro SD card upgrade mode Factory reset a...

Страница 11: ...the problem persists please contact your installer or Ocular Charging There is a critical error Unplug the charging plug from the EV immediately Turn OFF the pedestal charger and then back ON using th...

Страница 12: ...CHARGE WITH VISION...