2.2 Resistance Issues
You may need to remove one or more shrouds in order to diagnose resistance issues. Section 1.1 provides directions
for removing the shrouds.
Issue
Possible Cause
What to Do
Resistance is too high (rollers
are difficult to move on lowest
resistance setting).
Console setting is incorrect.
For shipping, the unit is set on the highest
resistance (level 20) to prevent linkage
movement during shipment. After power
is plugged in, the unit should automatically
reset itself to level 1.
Using the console arrow keys, verify that
the unit is set to level 1.
Brake cable is improperly
installed or aligned.
Inspect the servomotor and cable. The cable
must be installed correctly, positioned to
wrap around the top of the servomotor
pulley as it rotates counterclockwise to
increase resistance. On level one, the cable
and pulley should be positioned as shown
in Figure 2.5, with the notch on the pulley
oriented to “10 o’clock”. (Note: the arrow in
Figure 2.5 is for illustration only; no arrow
is imprinted on the pulley itself.)
Inspect the cable and brake. The brake
adjuster must be located at the bottom of
its slot when the machine is set to level 1
(Figure 2.6).
Use a screwdriver to gently push the brake
adjuster down to ensure that it is properly
positioned at the bottom of its slot.
If the brake is not fully disengaged or the
cable has too much slack when the cable
is properly installed and the brake adjuster
is in its proper position for level 1, you may
need to re-install or adjust the cable. Refer
to Section III for instructions.