Battery Replacement
The battery powers the digital display and illuminates the bubble level. It should
be replaced whenever the display flashes.
NOTE: Replacement of the battery will not affect the calibration of the balance
mechanism display.
1. Use a flat blade screwdriver to remove the 3 slotted screws in the battery cover
and remove the cover.
2. Carefully pull the battery out of its compartment as far as the wiring will allow.
3. Pull the connector off the terminals of the old battery and push it onto the
terminals of the new battery. For longer battery life it is recommended that you
use a 9v lithium battery. However, a standard 9v battery can also be used.
4. Replace the battery in its compartment, making sure that the wiring is not
twisted or pinched.
5. Replace the battery cover and tighten the 3 slotted screws.
6. Press the display actuator button and verify that the digital display and bubble
level are lit for approximately 15 seconds.