![OCI BDL800IR Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/oci/bdl800ir/bdl800ir_instruction-manual_3276957022.webp)
22
Chapter 5 Operating Instructions
5.2
Quick Start
5.2.1
Start-up
1.
Make sure all cables are properly connected (see Chapter 4 for details).
2.
Turn the power on. The instrument will probe the connection with the spectrometer
optics.
3.
Select
Instrument Mode
: LEED or AES.
4.
Set
Controller Mode
to Operating.
5.
Press the
Program Selection
knob to select a program. Highlight
Standard
by turn-
ing the knob. Press the
Select
button to confirm. All values will be updated to what
was previously set.
6.
Press the
Filament On/Off
button to turn the filament current on. The current will
slowly rise until it reaches its pre-set value. To pre-set a value see Section 5.2.2.
7.
Press the
Screen On/Off
button to turn the screen voltage on. The voltage will rise
until it reaches its pre-set value. To pre-set a value see Section 5.2.2.
8.
Press the
Beam Energy Control
knob to turn the beam energy on. The energy will
slowly rise until it reaches its pre-set value. To pre-set a value see Section 5.2.2.
9.
To change any of the values ad hoc, select the parameter you wish to change by press-
ing the corresponding button and adjust the value by turning the
Setting
knob.
5.2.2
Programming / Pre-Setting Parameters
1.
Change
Controller Mode
to Operating.
2.
Press the
Program Selection
knob and select a program you desire to alter—
highlight the program by turning the knob and press
Select
to confirm.
3.
Change
Controller Mode
to Programming.
4.
You have two options:
i.
Save all currently set/displayed values to the selected program by pressing
Save
.
ii.
Select a parameter you wish to change by pressing the corresponding button.
Adjust the value by turning the
Setting
knob and press
Save
to confirm the
change. Note that changing filament current or screen voltage requires these to
be turned off.
5.
Note that you may update all values of any program using the values of the Standard
program by pressing the
Program Selection
knob, highlighting
Copy Standard To
All
and pressing
Select
.
Содержание BDL800IR
Страница 1: ......
Страница 2: ......
Страница 10: ......
Страница 14: ......
Страница 20: ......
Страница 31: ...Chapter 6 Programming Menu 31...
Страница 32: ...32 Chapter 6 Programming Menu...
Страница 33: ...Chapter 7 Diagrams and Schematics 33 7 Diagrams and Schematics...
Страница 34: ...34 Chapter 7 Diagrams and Schematics...
Страница 35: ...Chapter 7 Diagrams and Schematics 35...
Страница 36: ...36 Chapter 7 Diagrams and Schematics...
Страница 37: ...Chapter 7 Diagrams and Schematics 37...
Страница 38: ...38 Chapter 7 Diagrams and Schematics...
Страница 39: ...Chapter 7 Diagrams and Schematics 39...
Страница 40: ...40 Chapter 7 Diagrams and Schematics...
Страница 41: ...Chapter 7 Diagrams and Schematics 41...
Страница 42: ...42 Chapter 7 Diagrams and Schematics...
Страница 43: ...Chapter 7 Diagrams and Schematics 43...
Страница 44: ...44 Chapter 7 Diagrams and Schematics...
Страница 45: ......
Страница 46: ...BDL800IR LMX ISH BACK VIEW...
Страница 47: ......
Страница 48: ......
Страница 49: ......
Страница 50: ......
Страница 51: ......
Страница 52: ......
Страница 53: ......
Страница 54: ......
Страница 58: ......
Страница 60: ...60 Chapter 9 Troubleshooting...
Страница 61: ...Chapter 9 Troubleshooting 61...