Page 11 of 13 

 

 

 

REGISTRATION

 

The National Institute for Occupational Safety and Health (NIOSH) requests, but does not require, 
that  purchasers of this respirator register each unit with NIOSH. Registration will enable NIOSH, 
which  approved this model of respirator, to attempt to notify you if a problem is discovered that 
might affect the  safety or performance of this respirator. Registration will also assist NIOSH in 
locating deployed units to  periodically evaluate whether this respirator model is remaining effective 
under field conditions of storage and use. 

Содержание EBA-75

Страница 1: ...Page 1 of 13 INSTRUCTION MANUAL FOR THE EBA 75 CLOSED CIRCUIT ESCAPE RESPIRATOR CCER CAPACITY 3 Manual Number NH24053 Revision A ECN 3590 December 14 2015...

Страница 2: ...EM DESCRIPTION OPERATION 3 OCENCO EBA 75 FUNCTIONAL DIAGRAM 4 INSTRUCTIONS FOR USE 5 INSTRUCTIONS FOR USE FOR USER AT REST 5 INSPECTION MAINTENANCE 6 INSPECTION CHECKLIST 7 OCENCO EBA 75 PARTS DIAGRAM...

Страница 3: ...ecting the unit as explained in the Instructions for Use section on page 5 and the Inspection and Maintenance section on page 6 2 Avoid physical abuse to the unit 3 Follow all NIOSH and MSHA recommend...

Страница 4: ...ves through the ON OFF valve into a pressure reducing regulator that reduces the oxygen pressure to 100 psi The oxygen then passes from the pressure reducing regulator through a hose and into the dema...

Страница 5: ...r donning the goggles prescription eyeglasses can be donned by guiding the eyeglass temples through the channels provided 12 ESCAPE Proper handling maintenance and other information as supplied in thi...

Страница 6: ...are provided one for each band If both seals are broken remove the unit from service 3 Inspect the apparatus for indications of abuse If the view through the case is obstructed such that a proper exam...

Страница 7: ...astic loops that hold the handle straps 13 One or both of the two handle straps black nylon straps missing or broken 14 Inspect the factory service date label on the base and remove unit if past the m...

Страница 8: ...13 5 PRESSUREGAUGE 4 MOUTHPIECE 3 GOGGLES 2 NOSECLIP 1 NECKHARNESS FROMLOW EREND OFSCRUBBER REGULATOR FROMDEMAND 6 11 MOUTHPIECE INHALATION 12 TO 5 7 3 4 1 ENDOFBREATHING FROMUPPER INHALATION 2 UPPER...

Страница 9: ...HANDLE STRAP 18 BAND 17 LATCH SEALS 16 LATCH RELEASE RINGS 15 LATCH PIN REQUIRED HANDLE STRAP ATTACHED TO BASE OPTIONAL SHOULDER STRAP ATTACHED TO COVER 18 14 17 STORE XXXX CARRY XXXX MFG XXXX REQUIRE...

Страница 10: ...from the date of manufacture if the units have been carried The end of service life for the EBA 75 is fifteen years from the date of manufacture regardless of the deployment method The Conditions of...

Страница 11: ...th NIOSH Registration will enable NIOSH which approved this model of respirator to attempt to notify you if a problem is discovered that might affect the safety or performance of this respirator Regis...

Страница 12: ...JMNO 1 PROTECTION SC Self contained ESC Escape CAP Capacity 2 CAUTIONS AND LIMITATIONS J Failure to properly use and maintain this product could result in injury or death M All approved respirators s...

Страница 13: ...Page 13 of 13 LakeView Corporate Park 10225 82nd Avenue Pleasant Prairie Wisconsin 53158 5801 United States of America Telephone 262 947 9000 Telefacsimilie 262 947 9020 www ocenco com...

Отзывы: