SLTH – SEMI-FLUSH THRESHOLD LIGHT 
INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE

 

 

 

 

1 -   Cable lead with plug 
2 -   Insulating strip-

insulating strip cable 

3 -  Insulating strips  
4 -  Insulating strips 

fastening screws  

5 -  Lamp supporting plate 

identification label 

6 -  Leak test valve 

Figure 5 – Lower cover optional fuse cutout – Inside view 

 

 

1 -   Cable lead with plug 
2 -   Relay-relay cable 
3 -  Electronic cutout 

relays  

4 -  Relays fastening 

screws  

5 -  Lampholder 

identification label 

6 -  Leak test valve 

Figure 6 – Lower cover with optional electronic cutout relays – Inside view 

 

Содержание SLTH

Страница 1: ...E AUTOMATIC KNOWLEDGE MANAGEMENT SYSTEM IT CAN BE SIGNED ON REQUEST THIS DOCUMENT AND THE DATA CONTAINED HERE IN IS PROPRIETARY PROPERTY AND SHALL NOT BE DUPLICATED USED OR DISCLOSED IN WHOLE OR IN PA...

Страница 2: ...dition 02 09 2010 SLTH SEMI FLUSH THRESHOLD LIGHT INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE EDITION Data 02 09 2010 Emission 03 13 2012 Second Edition REVISIONS Index Date Description Wr...

Страница 3: ...epaid by Purchaser to establish a claim under this warranty The cost of labour for the installation of a repaired or replaced Product shall be borne by Purchaser Replacement parts provided under the t...

Страница 4: ...ystem and check for voltage presence before accessing REANIMATION The maintenance staff must be aware of the risks related to electricity criteria to prevent the risk of electric shock and resuscitati...

Страница 5: ...RY WIRING 20 4 MAINTENANCE 20 4 1 REMOVING AND OPENING THE LIGHT UNIT FROM THE BASE 21 4 2 PRIMS CLEANING 21 4 2 1 Prism outside cleaning 21 4 2 2 Prism outside cleaning 21 4 3 PRISM REPLACEMENT 22 4...

Страница 6: ...d Part List 9 Figure 2 Complete P N identification 10 Figure 3 Dome Outside view 11 Figure 4 Dome Inside view 11 Figure 5 Lower cover optional fuse cutout Inside view 12 Figure 6 Lower cover with opti...

Страница 7: ...t through different positioning of the lamps In this way all lights result mechanically identical and the shallow base installation becomes very easy because no precise toe in is required during civil...

Страница 8: ...er is provided with one threaded hole for cable entry and external grounding screw with yellow green cable lead size 2 5 mm 2 0 460 m long with male faston terminal A suitable valve is outside mounted...

Страница 9: ...Vibration damping block 4 15 Spacer 4 16 HSCH M5x25 inox screw 4 17 5 inox grower washer 5 18 5x10x1 inox washer 7 19 O Ring 41150 silicone 1 20 O Ring 6850 silicone 1 21 Expanded PTFE strip 1 22 HSC...

Страница 10: ...Basic P N Colour G Green A Green FAA Toe in RI Left LI Right ST Straight Lamps 200 2x105W 6 6A reflectorized Mounting Assembly B Standard Shallow Base 12 dia O No Mounting Assembly Options F Fuse Cut...

Страница 11: ...nit fastening 3 Slot for dome removal 4 Painted area to identify the beam colour 5 Label with arrow for toe in identification Figure 3 Dome Outside view 1 Window to seat the prism 2 Through holes for...

Страница 12: ...sulating strip cable 3 Insulating strips 4 Insulating strips fastening screws 5 Lamp supporting plate identification label 6 Leak test valve Figure 5 Lower cover optional fuse cutout Inside view 1 Cab...

Страница 13: ...able entry The shallow base is designed for cementing in place by means of epoxy resin in a hole drilled in the pavement The fixture has to be fastened to the base by means of six hex cap screws compl...

Страница 14: ...n the specified limits All surfaces of the recess must be clean and dry If any of these surfaces is damp it is desirable that it be dried and blown clean with a compressed air blast The recess side wa...

Страница 15: ...15 of 28 Edition 03 13 2012 Supersedes edition 02 09 2010 SLTH SEMI FLUSH THRESHOLD LIGHT INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE Figure 8 Example of threshold configuration one trans...

Страница 16: ...be laid in cable ducts fig 10 Proceed as follow to realize a proper installation A B 1 Unscrew the six locking screws and remove the fixture from the base using the lifting tool P N 332 4140 or 332 4...

Страница 17: ...f sealer to the bottom of the drilled hole to assure a bond between the bottom of the light base and the drilled hole It may be necessary to place temporary plugs so as to block the wireways entrances...

Страница 18: ...should be filled with sealer up to approx 25 mm from the pavement according to the local needs Fill the remaining 25 mm with a suitable joint sealing filler 11 Lay the secondary power cable equipped...

Страница 19: ...NANCE 1 Positioning jig 2 Align the jig notch with the mark on the pavement 3 Circular level 4 Screws and spacers for the jig mounting 5 Lobe knob for positioning jig levelling 6 Shallow base notches...

Страница 20: ...installation tightening torque is 25 Nm The fixture is subject to optical misalignment and or mechanical damage if not properly seated 4 3 SECONDARY WIRING The IEC 61823 International Standard AGL ser...

Страница 21: ...screws HSCH M5x16 fig 1 n 22 If the lower cover assembly is hard to remove it is possible to use two of these screws in two threaded holes close to the locking holes Every time the fixture is removed...

Страница 22: ...1 Removing the prism Remove the fixture from the base and open the fixture as described at paragraph 4 1 Clean out possible pieces of the old prism and all accumulated debris from the inside Remove t...

Страница 23: ...fig 1 n 8 9 and fix it to the dome using the relevant screws BHC M5x10 fig 1 n 10 Inspect all components ins ide the fixture for damages or signs of corrosion Replace all necessary components Reassemb...

Страница 24: ...et is dimensioned to allow the proper positioning when compressed between the mating surfaces Screws properly tightened are important in obtaining a complete seal TIGHTENING TORQUE lower cover HSCH M5...

Страница 25: ...ctions of par 4 2 5 9 PRESSURE VALVE If a leakage is found through the pressure valve during an air pressure test check carefully where the leakage happens If the leakage is between the valve fig 5 6...

Страница 26: ...dictated by the weather and the location of the fixtures 5 11 3 SNOWPLOW OPERATIONS Snowplow operators should exercise extra care not to strike the light fixtures with snowplow blades After snow remo...

Страница 27: ...t once every three months or more frequently during the two four weeks following the reinstallation of a serviced fixture 5 11 6 LEAKAGE TEST If any fixture contains water remove the water and clean a...

Страница 28: ...ten halogen 6 6 A with dichroic reflector 1 13 153 0040 Dichroic GREEN filter complete with holder for SLTH G 153 0070 Dichroic GREEN filter complete with holder for SLTH A 1 8 9 318 1130 Prism 1 3 32...

Отзывы: