4.5 disassembling, cleaning and sanitation of the of the beater
assembly
After the discharge door been removed, then it is possible to remove the beater assemble
from the machine.
1. Pull out the beater assemble and remove the ripple seal ring.
2. Place the two parts in a container with sanitizer for 10 minutes.
3. Rinse the part with cold drinking water.
4. Dry the parts with air or with a clean towel.
NOTE: Remember to put a thin layer of lubricant as shown on the picture bellow.
IMPORTANT: Remember to always ensure that the cooling cylinder been drained of
water after it been cleaned or sanitized.
Picture 19: beater lubrication