RUN TIMER
The GAUG Mode Set Utilities Menu includes an item that allows a Run Timer to be added to the GAUG Dive Main screen.
SET RUN TIMER,
information includes (Fig. 107):
> Graphic RUN TIMER.
> Graphics OFF and ON with the Arrow ( > ) icon next to the one previously saved fl ashing.
• S (2 sec) - to revert to the Set Utilities Menu.
• A or M (< 2 sec) - to toggle between OFF and ON*.
• S (< 2 sec) - to save the setting and revert to the Set Utilities Menu.
*Selecting ON will enable the Timer, not start it. That is accomplished while in Dive Mode.
---------------------------------------------------------------------------------------------------------
Upon descent to 5 FT (1.5 M) for 5 seconds, operation will enter GAUG Dive Mode.
GAUG DIVE MAIN,
information includes (Fig. 108A/B) -
> Current Depth with FT (or M) icon.
> Run Time (hr:min) with graphic TIMER, 0:00 until started, up to 9:59; blank if set OFF.
> Elapsed Dive Time (hr:min) with graphic EDT.
> Graphic TMT - 1 (or 2, 3, 4), one in use.
> Air Time Remaining (up to 99 min) with min and ATR icons, blank if no TMT in use, 99 when => 99.
> Tank Pressure, for the TMT currently in use, with PSI (or BAR) and Link icons.
If no TMT is in use, the graphic SPG (meaning
Submersible Pressure Gauge) will be displayed with no icons and no ATR.
> VARI with icon, while ascending.
• A (< 2 sec) - to access ALT.
• M (< 2 sec) - to apply a snapshot Earmark to the PCI data recorded at that time.
The graphics EARMARK APPLIED will be
displayed in place of the Timer and EDT for 3 seconds (Fig. 108C).
• M (2 sec) - to access the TMT Switch Menu.
• S (< 2 sec) - to acknowledge alarms.
• S (2 sec) - to access the Compass Operating Main.
• L (< 2 sec) - to toggle the Backlight On/Off.
• L (2 sec), while the Backlight is On - to reset the timer and keep it On for the duration time set.
GAUG DIVE ALT,
information includes (Fig. 109) -
> Max Depth with FT (or M) and MAX icons.
> Time of Day (hr:min_sec), with A (or P) if 12 Hour.
> Temperature with ° icon and graphic F (or C).
• A or M (< 2 sec) - to revert to Main.
• Revert to the Main after 10 seconds, if A or M is not pressed.
• L (< 2 sec) - to toggle the Backlight On/Off.
• L (2 sec), while the Backlight is On - to reset the timer and keep it On for the duration time set.
DELAYED VIOLATION 3 (DV3)
Upon descent deeper than 330 FT (100 M), the Audible will sound and the LED will fl ash. The graphic UP with Up Arrow icons
will be displayed fl ashing, signifying that you are out of range, until ascent is made above 330 FT (100 M).
Upon ascending above 330 FT (100 M), graphic UP with Up Arrow icons will be removed.
DV3 MAIN,
information includes (Fig. 110) -
> Current Depth with FT (or M) icon.
> Run Time (hr:min) with graphic TIMER, 0:00 until started, up to 9:59; blank if set OFF.
> Elapsed Dive Time (hr:min) with graphic EDT.
> Graphic TMT - 1 (or 2, 3, 4), one in use.
> Air Time Remaining (up to 99 min) with min and ATR icons.
> Graphic UP with Up Arrows, fl ashing.
> Tank Pressure, for the TMT currently in use, with PSI (or BAR) and Link icons.
> VARI with icon, while ascending.
• A (< 2 sec) - to access ALT.
• M (2 sec) - to access the TMT Switch Menu.
• S (< 2 sec) - to acknowledge alarms.
• S (2 sec) - to access the Compass Operating Main.
• L (< 2 sec) - to toggle the Backlight On/Off.
• L (2 sec), while the Backlight is On - to reset the timer and keep it On for the duration time set.
DV3 ALT
- similar to the Dive ALT.
Fig. 107 - SET RUN TIMER
Fig. 108A - GAUG DIVE MAIN
(Run Timer set OFF)
Fig. 109 - GAUG DIVE ALT
Fig. 110 - GAUG DV 3 MAIN
(Run Timer set OFF)
Fig. 108B - GAUG DIVE MAIN
(Run Timer set ON)
Fig. 108C - GAUG DIVE MAIN
(shown for 3 seconds)
Содержание OCi
Страница 1: ...1 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 OCi DIVE COMPUTER OPERATING MANUAL...
Страница 5: ...5 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 FEATURES AND FUNCTIONS...
Страница 11: ...11 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 WATCH MODE...
Страница 16: ...16 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 NORM SURFACE MODES...
Страница 28: ...28 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 DIVE MODE FEATURES...
Страница 33: ...33 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 NORM DIVE MODE...
Страница 40: ...40 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 NORM GAS TMT SWITCHING...
Страница 42: ...42 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 DIGITAL GAUGE OP MODE...
Страница 47: ...47 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 FREE DIVE TECH FREE DIVE OP MODES...
Страница 61: ...61 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 COMPASS MODE...
Страница 70: ...70 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 TECHNICAL DATA...
Страница 76: ...76 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 OCi DIVE COMPUTER OPERATING MANUAL...